• Acta Optica Sinica
  • Vol. 31, Issue 7, 730001 (2011)
Wei Ruyi1、2、3、*, Zhang Xuemin2、3, Zhou Jinsong4, Zhou Sizhong2, Gao Xiaohui1、2、3, Wei Junxia1、2、3, and Wang Le1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • show less
    DOI: 10.3788/aos201131.0730001 Cite this Article Set citation alerts
    Wei Ruyi, Zhang Xuemin, Zhou Jinsong, Zhou Sizhong, Gao Xiaohui, Wei Junxia, Wang Le. Calculations on Optical Path Difference of a High Resolution Reflecting Scanning Fourier Transform Spectrometry[J]. Acta Optica Sinica, 2011, 31(7): 730001 Copy Citation Text show less
    References

    [1] R. J. Bell. Introductory Fourier Transform Spectroscopy[M]. New York: Academic Press, 1972

    [2] Wu Jinguang. Applications of Fourier Transform Infrared Spectroscopy[M]. Beijing: Sci. & Tech. Press, 1994. 54~56

    [3] W. Wadsworth, J. P. Dybwad. Ultra high speed chemical imaging spectrometer[C]. SPIE, 1997, 3082: 148~194

    [4] W. Wadsworth, J. P. Dybwad. A very fast imaging FT spectrometer for on line process monitoring and control[C]. SPIE, 1998, 3537: 54~61

    [5] P. R. Griffiths, B. L. Hirsche, C. J. Manning. Ultra-rapid-scanning Fourier transform infrared spectrometry[J]. Vibrational Spectroscopy, 1999, 19(1): 165~176

    [6] Yang Xiaoxu, Zhou Sizhong, Xiangli Bin et al.. Studies on nonlinearity of optical path difference of rotary Fourier transform spectrometer[J]. Acta Optica Sinica, 2004, 24(10): 1388~1392

    [7] Su Xing, Huang Huimin, Xiangli Bin. Analyses of nonlinearity of high resolution spectrometer oriented on high speed rotating reflector[J]. Acta Photonica Sinica, 2001, 30(12): 1474~1480

    [8] Yuan Yan, Xiangli Bin. Rotary high sensitive interference spectral imager (ROSI)[J]. Acta Photonica Sinica, 2005, 34(6): 935~938

    [9] Zhang Wenxi, Xiangli Bin, Yuan Yan et al.. Ultra-rapid-scanning imaging interferometer[J]. Acta Photonica Sinica, 2006, 35(8): 1153~1155

    [10] Zhou Jinsong, Wei Ruyi, Li Siyuan et al.. High resolution ultra-rapid scanning Fourier transform spectrometry[C]. OSA Technical Digest in Fourier Transform Spectroscopy, 2009, FTuB5

    [11] Huang Jian, Xian Hao, Jiang Wenhan et al.. The reflected beam′s phase aberration induced by the fabrication errors of corner cube retroreflector[J]. Acta Optica Sinica, 2009, 29(7): 1951~1955

    [12] Hu Yuxi, An Liansheng. Applied Optics[M]. Hefei: USTC Press, 1996. 8

    CLP Journals

    [1] Zhang Xuemin, Wei Ruyi, Yan Su, Duan Jiayou, Li Hua, Yang Jianfeng. Precise Alignment of Separated Sagnac Interferometer[J]. Chinese Journal of Lasers, 2013, 40(4): 416001

    Wei Ruyi, Zhang Xuemin, Zhou Jinsong, Zhou Sizhong, Gao Xiaohui, Wei Junxia, Wang Le. Calculations on Optical Path Difference of a High Resolution Reflecting Scanning Fourier Transform Spectrometry[J]. Acta Optica Sinica, 2011, 31(7): 730001
    Download Citation