• Matter and Radiation at Extremes
  • Vol. 5, Issue 3, 035402 (2020)
Xiangcao Li, Bao’an Liu, Chunyan Yan, Jie Ren, Chang Liu, and Xin Jua)
Author Affiliations
  • Department of Physics, University of Science and Technology Beijing, Beijing 100083, China
  • show less
    DOI: 10.1063/1.5143289 Cite this Article
    Xiangcao Li, Bao’an Liu, Chunyan Yan, Jie Ren, Chang Liu, Xin Ju. Defects of laser-irradiated KDP crystals with different fluences studied by photoluminescence spectroscopy[J]. Matter and Radiation at Extremes, 2020, 5(3): 035402 Copy Citation Text show less
    (a) Spectrum of light source. (b) and (c) PL emission spectra from a KDP crystal at different damage sites.
    Fig. 1. (a) Spectrum of light source. (b) and (c) PL emission spectra from a KDP crystal at different damage sites.
    Experimental spectra (black solid curves), simulated spectra (red dashed curves), and Gaussian fits (blue dashed curves): (a) excitation light source; (b) and (c) PL emission spectra of a KDP crystal at different damage sites.
    Fig. 2. Experimental spectra (black solid curves), simulated spectra (red dashed curves), and Gaussian fits (blue dashed curves): (a) excitation light source; (b) and (c) PL emission spectra of a KDP crystal at different damage sites.
    PL decay kinetics at 600 nm of a KDP crystal. The plots labeled (b) and (c) correspond to the spectra in Figs. 2(b) and 2(c), respectively. The black solid curves are the experimental spectra, and the red dashed curves are double-exponential simulated spectra.
    Fig. 3. PL decay kinetics at 600 nm of a KDP crystal. The plots labeled (b) and (c) correspond to the spectra in Figs. 2(b) and 2(c), respectively. The black solid curves are the experimental spectra, and the red dashed curves are double-exponential simulated spectra.
    PositionArea (a.u.)FWHM (nm)
    Peakabcabcabc
    A1417.92418.43418.084.254.404.135.276.125.75
    A2424.10426.66426.044.416.383.9913.6820.8514.16
    B467.96473.4915.1617.5952.8776.05
    C510.95512.919.5614.1146.4458.64
    D550.50560.0915.6822.0073.8179.51
    E587.8929.70152.81
    F635.1434.22216.69
    Table 1. Parameters of peaks with Gaussian fitting for samples irradiated by different fluences.
    BCDEF
    Position (nm)467510560587635
    9.0 J/cm2 fluence (%)10092.910052.029.6
    Retired (%)10094.010054.113.5
    11.5 J/cm2 fluence (%)10098.810085.52.40
    Table 2. Probabilities of different types of defects.
    I1τ1 (ns)I2τ2 (ns)
    b0.504.040.610.74
    c0.554.232.690.04
    Table 3. Parameters of PL decay kinetics at 600 nm.
    Xiangcao Li, Bao’an Liu, Chunyan Yan, Jie Ren, Chang Liu, Xin Ju. Defects of laser-irradiated KDP crystals with different fluences studied by photoluminescence spectroscopy[J]. Matter and Radiation at Extremes, 2020, 5(3): 035402
    Download Citation