• Acta Optica Sinica
  • Vol. 33, Issue 5, 522004 (2013)
Zheng Shaolin1、2、*, Liu Yongji1、2, Wang Zhaoqi1、2, and Kong Xiangming3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3788/aos201333.0522004 Cite this Article Set citation alerts
    Zheng Shaolin, Liu Yongji, Wang Zhaoqi, Kong Xiangming. Design of Optical System for a Novel Imaging Keratometer[J]. Acta Optica Sinica, 2013, 33(5): 522004 Copy Citation Text show less
    References

    [1] David L. Rogers, G. Rick Whitehead, Julie A. Stephens et al.. Corneal power measurements in fixating versus anesthetized nonfixating children with a handheld keratometer [J]. J. American Association for Pediatric Ophthalmology and Strabismus, 2010, 14(1): 11~14

    [2] William A. Douthwaite, Edward A. H. Mallen. Verification of conicoidal concave surfaces by keratometry [J]. J. Optometry, 2010, 3(2): 115~121

    [3] Wolfgang Haigis. Challenges and approaches in modern biometry and IOL calculation [J]. Saudi J. Ophthalmology, 2012, 26(1): 7~12

    [4] Ron Gutmark, David L. Guyton. Origins of the keratometer and its evolving role in ophthalmology [J]. Survey of Ophthalmology, 2010, 55(5): 481~497

    [5] Lü Fan, Xu Liang. Optometry Instruments [M]. Beijing: People′s Medical Publishing House, 2004. 21~28

    [6] Qu Jia. Optometry Theory and Method [M]. Beijing: People′s Medical Publishing House, 2004. 129~132

    [7] Andrew K. C. Lam, Rufina Chan, Roger Chiu. Effect of instrument rotation on handheld keratometer [J]. J. Cataract & Refractive Surgery, 2004, 30(12): 2590~2594

    [8] Zhao Junqi, Guo Zhiyong, Chen Anshi et al.. Auto-ophthalmometer of eye based on image processing [J]. Chinese Journal of Biomedical Engineering, 2011, 30(1): 100~104

    [9] Zhao Junqi, Duan Peihua, Guo Zhiyong et al.. Design of subpixel algorithm of dioptric parameter measurement system for eye cornea [J]. Journal of North University of China, 2011, 32(3): 362~366

    [10] Zhang Yimo. Applied Optics [M]. Beijing: Publishing House of Electronics Industry, 2008. 26~40

    [11] Xu Shiwen. Optical Metrology [M]. Harbin: Harbin Institute of Technology Press, 1988. 179~182

    [12] J. Warren Blaker. Toward an adaptive model of the human eye [J]. J. Opt. Soc. Am., 1980, 70(2): 220~223

    CLP Journals

    [1] Chen Peng, Wang Cheng, Zheng Gang, Chen Minghui, Xiang Huazhong, Zhang Dawei. Optimization design and realization of a keratometer[J]. Opto-Electronic Engineering, 2019, 46(1): 180373

    [2] Chen Zhijie, Li Dahai, Zhang Chen, Song Yuwei, Xu Wenfeng, Huang Yi. Study of Anterior Corneal Surface Design Based on Reverse Ray-Tracing Method[J]. Laser & Optoelectronics Progress, 2015, 52(6): 62204

    [3] Sui Chenghua, Han Yonghao, Xu Danyang, Gao Nan, Gao Jianxun, Wo Shengjie, Du Chunnian. Real-time Image Detection in Corneal Topography[J]. Acta Optica Sinica, 2017, 37(6): 611001

    [4] Li Hongzhuang, Zhang Zhenduo. Design of 20× Double-Linkage Continuous Zoom Optical System[J]. Acta Optica Sinica, 2015, 35(2): 222003

    [5] Zhang Xueying, Wang Jinsong, Huang Guolin, Xu Pengfei. Design of optical system for high accuracy imaging keratometry[J]. Opto-Electronic Engineering, 2019, 46(1): 180392

    [6] Sui Chenghua, Wo Shengjie, Gao Nan, Xu Danyang, Han Yonghao, Du Chunnian. Design and Implementation of Imaging System for Corneal Topography Based on Placido Disk[J]. Acta Optica Sinica, 2016, 36(12): 1222001

    Zheng Shaolin, Liu Yongji, Wang Zhaoqi, Kong Xiangming. Design of Optical System for a Novel Imaging Keratometer[J]. Acta Optica Sinica, 2013, 33(5): 522004
    Download Citation