• Laser & Optoelectronics Progress
  • Vol. 53, Issue 8, 81408 (2016)
Hao Xiaojian*, Zhang Genfu, and Zan Qingbo
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/lop53.081408 Cite this Article Set citation alerts
    Hao Xiaojian, Zhang Genfu, Zan Qingbo. Thermocouple Time Constant Test System and Uncertainty Analysis Based on Semiconductor Lasers[J]. Laser & Optoelectronics Progress, 2016, 53(8): 81408 Copy Citation Text show less
    References

    [1] Zhang Genfu, Hao Xiaojian, Sang Tao, et al. Study on the dynamic response of thermocouple temperature sensor[J]. China Measurement & Test, 2015, 41(10): 68-72.

    [2] Lei Sheng, Ren Jingming, Shi Chao, et al. Impact toughness and fracture mechanism of the surface laser hardened components of 45 steel[J]. Laser & Optoelectronics Progress, 2015, 52(1): 011408.

    [3] Fu FuXing, Chang Gengrong, Zhao Xiaoxia, et al. Influence of laser spot diameter on cladding layer cracking[J]. Laser & Optoelectronics Progress, 2015, 52(3): 031401.

    [4] Chen Hong, Li Zhuguo, Yao Chengwu, et al. Research on microstructure and properties of fiber laser repairing ZM5 magnesium alloy thin-walled casting[J]. Chinese J Lasers, 2015, 42(2): 0203002.

    [5] Wu Fang, Yang Xinyuan, Wang Li. Study on measuring time constants of surface temperature sensors[J]. Metrology & Measurement Technology, 2014, 34(4): 60-62.

    [7] Yang Yu. Test analysis of rise time of semiconductor laser based on thermocouple dynamic calibration system[J]. Electro-Optic Technology Application, 2014, 29(2): 95-98.

    [8] Zan Qingbo, Hao Xiaojian, Zhou Hanchang. Design of laser light path of optical fiber coupling lens[J]. Laser & Optoelectronics Progress, 2015, 52(10): 102201.

    [9] Fang Zheng, Pan Yi, Jiang Yuejun, et al. Study on evaluation methods for weighing relative standard uncertainty of gas reference materials prepared by weighing method[J]. China Measurement & Test, 2012, 38(6): 5-8.

    [10] Chen Guisheng, Fu Zhiyong, Zhao Jing, et al. Research on improving method of the credibility of industrial platinum resistance verification results at a low cost[J]. China Measurement & Test, 2015, 41(1): 24-28.

    [11] General Administration of Quality Supervision, Inspection and Quarantine of the People′s Republic of China. Evaluation and expression of uncertainty in measurement: JJF1059.1-2012[S]. Beijing: China Zhijian Publishing House, 2013.

    CLP Journals

    [1] Hu Xiaotao, Hao Xiaojian, Duan Xianggang. Temperature Measurement Technology Based on Double Line of Atomic Emission Spectra[J]. Laser & Optoelectronics Progress, 2017, 54(10): 100201

    Hao Xiaojian, Zhang Genfu, Zan Qingbo. Thermocouple Time Constant Test System and Uncertainty Analysis Based on Semiconductor Lasers[J]. Laser & Optoelectronics Progress, 2016, 53(8): 81408
    Download Citation