• Laser & Optoelectronics Progress
  • Vol. 55, Issue 4, 040102 (2018)
Bingyang Wu1, Jinlong Yu1, Ju Wang、*, and Wenrui Wang1
Author Affiliations
  • 1 Laboratory of Optical Fiber Communications, School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
  • 1 School of Aeronautics and Astronautics, Zhejiang University, Hangzhou, Zhejiang 310058, China
  • show less
    DOI: 10.3788/LOP55.040102 Cite this Article Set citation alerts
    Bingyang Wu, Jinlong Yu, Ju Wang, Wenrui Wang. Accuracy Correction of Miniaturization Device for Air Refractive Index Measurement[J]. Laser & Optoelectronics Progress, 2018, 55(4): 040102 Copy Citation Text show less
    References

    [1] Luo Z F, Zhang K, Wang Z G et al. Pose calibration of laser range finder in automated guided vehicle[J]. Laser & Optoelectronics Progress, 54, 062802(2017).

    [2] Coddington I, Swann W C, Nenadovic L et al. Rapid and precise absolute distance measurements at long range[J]. Nature Photonics, 3, 351-356(2009). http://www.nature.com/nphoton/journal/v3/n6/abs/nphoton.2009.94.html

    [3] Baumann E, Giorgetta F R, Deschênes J D et al. Comb-calibrated laser ranging for three-dimensional surface profiling with micrometer-level precision at a distance[J]. Optics Express, 22, 24914-24928(2014). http://www.ncbi.nlm.nih.gov/pubmed/25401525

    [4] Chen Q H, Yan J Q, Liu Z Y et al. An air refractometer with dual vacuum chambers eased on the method of equivalent synthetic wave[J]. Acta Metrologica Sinica, 25, 203-206(2004).

    [5] Birch K P, Downs M J. Anupdated edlén equation for the refractive index of air[J]. Metrologia, 30, 155-162(1993). http://iopscience.iop.org/0026-1394/30/3/004?rel=sem&relno=4

    [6] Li D G, Zhang G X. Measurement and compensation for refractive index of air using a pre-evacuated airtight sealed cavity[J]. Optics and Precision Engineering, 9, 80-84(2001).

    [7] Edlén B. The refractive index of air[J]. Metrologia, 2, 71-80(1966). http://ci.nii.ac.jp/naid/30003278773

    [8] Chen Q H, Liu J H, Luo H F et al. Correction to the calculation equations of moist air refractive index at the wavelength of 633 nm[J]. Chinese Journal of Lasers, 41, 0308002(2014).

    [9] Fendley J J. Measurement of refractive index using a Michelson interferometer[J]. Physics Education, 17, 209-211(1982). http://eric.ed.gov/?id=EJ270258

    [10] Wang Q L, Li J Y, Shen H K. Target tracking system of binocular vision and laser range sensor[J]. Acta Optica Sinica, 36, 0912002(2016).

    [11] Ni Y C. Modification of the air refractive index edling formula[J]. Measurement Technique, 33, 22-27(1998).

    [12] Wexler A. Vapor pressure formulation for water in range 0 to 100 ℃. A revision[J]. Journal of Research of the National Bureau of Standards, Section A: Physics and Chemistry, 80A, 775-785(1976). http://www.researchgate.net/publication/277403356_Vapor_pressure_formulation_for_water_in_range_0_to_100C_A_Revision

    [13] Jin Q F. Research on the impacts of refractive index[D]. Hangzhou: Zhejiang University(2006).

    [14] Yang J J, Huang L. The application of digital humidity and temperature sensor SHT75[J]. Journal of Changzhou Institute of Technology, 22, 31-33(2009).

    [15] Miller D J, Sun K, Tao L et al. Open-path, quantum cascade-laser-based sensor for high-resolution atmospheric ammonia measurements[J]. Atmospheric Measurement Techniques, 7, 81-93(2014). http://adsabs.harvard.edu/abs/2014AMT.....7...81M

    [16] Meng Q B, Qi Y J, Lu Z X et al. Analysis of effect of ambient temperature variation on measurement accuracy of Shack-Hartmann wavefront wensor[J]. Chinese Journal of Lasers, 43, 0810001(2016).

    [17] Batagelj V, Bojkovski J, Drnovšek J. Methods of reducing the uncertainty of the self-heating correction of a standard platinum resistance thermometer in temperature measurements of the highest accuracy[J]. Measurement Science and Technology, 14, 2151-2158(2003). http://www.iop.org/EJ/abstract/0957-0233/14/12/016

    [18] Kung J T, Lee H S. An integrated air-gap-capacitor pressure sensor and digital readout with sub-100 attofarad resolution[J]. Journal of Microelectromechanical Systems, 1, 121-129(1992). http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=186391

    [19] Hei K F, Yu J L, Wang J et al. Variable frequency range finding technology based on double polarization modulation method and system implementation[J]. Acta Physica Sinica, 63, 100602(2014).

    [20] Xiao Y, Yu J L, Wang J et al. Relationship between modulation frequency and range accuracy in the double polarization modulation range finding system[J]. Acta Physica Sinica, 65, 100601(2016).

    Bingyang Wu, Jinlong Yu, Ju Wang, Wenrui Wang. Accuracy Correction of Miniaturization Device for Air Refractive Index Measurement[J]. Laser & Optoelectronics Progress, 2018, 55(4): 040102
    Download Citation