• Infrared and Laser Engineering
  • Vol. 44, Issue 2, 407 (2015)
Bai Yu1、2、3、*, Liao Zhiyuan1, Li Hua1, Cheng Ximin1、3, Xing Tingwen1, and Jiang Yadong2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: Cite this Article
    Bai Yu, Liao Zhiyuan, Li Hua, Cheng Ximin, Xing Tingwen, Jiang Yadong. Design and analyse on catadioptric MWIR athermal imaging system[J]. Infrared and Laser Engineering, 2015, 44(2): 407 Copy Citation Text show less

    Abstract

    The temperature influence of each parameter in infrared detection imaging system was analyzed in the paper.Benefitting from infrared chalcogenide glasses less index temperature coefficient and catadioptric configuration excellent thermalization performance, a catadioptric MWIR detection thermalization imaging system by Code-v optical design software was presented.The working wavelength is 3.7-4.8 μm,effective focal length is 109.7 mm,field of view was 6.4°,F/# is 2.0 and cold shield efficiency was 100%.The design results indicate that the image quality in -40 ℃ and 60 ℃ have little changed, which compared with in 20 ℃.The system is compatible with staring focal plane array MWIR detector which has a format of 320×256 and the pixel pitch of 30 μm.
    Bai Yu, Liao Zhiyuan, Li Hua, Cheng Ximin, Xing Tingwen, Jiang Yadong. Design and analyse on catadioptric MWIR athermal imaging system[J]. Infrared and Laser Engineering, 2015, 44(2): 407