• Acta Optica Sinica
  • Vol. 43, Issue 5, 0506002 (2023)
Chunhui Luo1, Xiaoxu Chen1, and Shun Wu1、2、*
Author Affiliations
  • 1Hubei Key Laboratory of Optical information and Pattern Recognition, Wuhan Institute of Technology, Wuhan 430205, Hubei, China
  • 2State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, Shaanxi, China
  • show less
    DOI: 10.3788/AOS221550 Cite this Article Set citation alerts
    Chunhui Luo, Xiaoxu Chen, Shun Wu. Analysis of Sensing Characteristics of Parallel Fabry-Pérot Interferometer Based on Vernier Effect[J]. Acta Optica Sinica, 2023, 43(5): 0506002 Copy Citation Text show less
    Schematic diagram of gas pressure sensing device
    Fig. 1. Schematic diagram of gas pressure sensing device
    Optical vernier spectra produced by I1 and I2 superposition under different j. (a) j=1; (b) j=2; (c) j=3; (d) j=4
    Fig. 2. Optical vernier spectra produced by I1 and I2 superposition under different j. (a) j=1; (b) j=2; (c) j=3; (d) j=4
    Vernier spectra and FFT diagrams under different j in experiment. (a)(b) j=1; (c)(d) j=2; (e)(f) j=3; (g)(h) j=4
    Fig. 3. Vernier spectra and FFT diagrams under different j in experiment. (a)(b) j=1; (c)(d) j=2; (e)(f) j=3; (g)(h) j=4
    Gas pressure test results for sample S1. (a) Drift diagram of internal envelope reference point corresponding to S1 under different air pressures; (b) gas pressure sensitivity corresponding to S1 (inset shows side-view microscopic pictures of sensing and reference Fabry-Pérot interferometers)
    Fig. 4. Gas pressure test results for sample S1. (a) Drift diagram of internal envelope reference point corresponding to S1 under different air pressures; (b) gas pressure sensitivity corresponding to S1 (inset shows side-view microscopic pictures of sensing and reference Fabry-Pérot interferometers)
    Vernier spectra and their characteristics for different IA to IB ratios under constant IA.(a) IA∶IB=2.5∶1.0; (b) IA∶IB=3.5∶1.0; (c) IA∶IB=4.5∶1.0
    Fig. 5. Vernier spectra and their characteristics for different IA to IB ratios under constant IA.(a) IAIB=2.5∶1.0; (b) IAIB=3.5∶1.0; (c) IAIB=4.5∶1.0
    Influence of IB on envelope feature points under constant IA. (a) IA∶IB=1∶1; (b) IA∶IB=3∶1
    Fig. 6. Influence of IB on envelope feature points under constant IA. (a) IAIB=1∶1; (b) IAIB=3∶1
    Cutting error corresponding to different reference cavity media as function of detuning ratio and sensitivity at L1=300 μm and j=1. (a) Detuning ratio; (b) sensitivity
    Fig. 7. Cutting error corresponding to different reference cavity media as function of detuning ratio and sensitivity at L1=300 μm and j=1. (a) Detuning ratio; (b) sensitivity
    Chunhui Luo, Xiaoxu Chen, Shun Wu. Analysis of Sensing Characteristics of Parallel Fabry-Pérot Interferometer Based on Vernier Effect[J]. Acta Optica Sinica, 2023, 43(5): 0506002
    Download Citation