• Spectroscopy and Spectral Analysis
  • Vol. 34, Issue 9, 2533 (2014)
YUAN Jun-jie1、*, XIE You-zhuan1, HAN Chen1, SUN Wei1, ZHANG Kai1, ZHAO Jie1, LU Xiao2, LU Jian-xi2, and REN Wei3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3964/j.issn.1000-0593(2014)09-2533-05 Cite this Article
    YUAN Jun-jie, XIE You-zhuan, HAN Chen, SUN Wei, ZHANG Kai, ZHAO Jie, LU Xiao, LU Jian-xi, REN Wei. Determination of Trace Element Silver in Animal Serum, Tissues and Organs by Microwave Digestion-ICP-MS[J]. Spectroscopy and Spectral Analysis, 2014, 34(9): 2533 Copy Citation Text show less

    Abstract

    Nowadays, the silver is widely used in the biological field and its biological safety catches great attention. It is important to know the distribution of silver ions within the biological organism and the toxic threshold concentration in the tissue. Therefore, a highly sensitive method for measurement of trace amount of silver ion in the medical biological samples is needed. With its high sensitivity for detection of metal ions, inductively coupled plasma mass spectrometry (ICP-MS) method is well suited for quantification of trace amount of silver ion in such samples, but method development is still in its infancy. Consequently, a simple and convenient method for determination of trace amount of silver in the animal serum, tissues or organs was developed, in which the samples were subjected to the microwave digestion, followed by the ICP-MS analysis. To begin with, the samples of serum, muscle, bone marrow, bone, heart, liver, spleen, and kidney were sequently processed in 5 mL of HNO3 and 2 mL of H2O2 solution. Then the samples were completely digested by microwave with the power of 2 000 watts. The temperature was raised gradually by 3-step program. Moreover, the data achieved were reproducible and the method was time saving and especially for large amounts of sample processing. Then the digested solutions were diluted to constant volume. Finally, the concentration of 107Ag in the samples was analyzed by the method of ICP-MS under the optimized conditions. Element yttrium (Y) was used as the internal standard to compensate for matrix suppression effect and improve the accuracy of measurement. For one thing, the analytical results showed that the detection limit of the trace element 107Ag was 0.98 μg·kg-1, and furthermore, the correlation coefficient of standard curve was 0.999 9. For another thing, the recovery rate of the silver element ranged from 98% to 107%, which was calculated according to measured quantity before adding standard, adding standard and measured quantity after adding standard. At the same time, the relative standard deviation (RSD) of the method was in the range of 2.0%~4.3%. The concentrations of element silver in animal serum, tissues and organs were determined by the aboved method. The obtained results showed that silver ions were mainly accumulated in the liver after they were intaken into the body. The results suggested that the microwave digestion-ICP-MS method could accurately determine the trace element Ag in the body. The method developed has good feasibility and is suitable for the determination of trace element Ag in various types of medical and biological samples, especially for large quantities of biological samples. The process has the advantages of easy sample processing and it is simple and convenient. In addition, the accurate results could be obtained in a short time with high sensitivity. Last but not least, the method provides the guidance for the determination of trace elements in other biological samples.
    YUAN Jun-jie, XIE You-zhuan, HAN Chen, SUN Wei, ZHANG Kai, ZHAO Jie, LU Xiao, LU Jian-xi, REN Wei. Determination of Trace Element Silver in Animal Serum, Tissues and Organs by Microwave Digestion-ICP-MS[J]. Spectroscopy and Spectral Analysis, 2014, 34(9): 2533
    Download Citation