    Schematic diagram of the Vπ measurement system.
    Fig. 1. Schematic diagram of the Vπ measurement system.
    Performance tested result of Vπ.
    Fig. 2. Performance tested result of Vπ.
    Relationship of Vπ versus λ at different temperatures.
    Fig. 3. Relationship of Vπ versus λ at different temperatures.
    Configuration of the experimental IFOG.
    Fig. 4. Configuration of the experimental IFOG.
    Wavelength shift and SF errors at different temperatures.
    Fig. 5. Wavelength shift and SF errors at different temperatures.
    Radiation experiment photograph.
    Fig. 6. Radiation experiment photograph.
    Tested SF error, mean wavelength and the SF calculated with the tested mean wavelength.
    Fig. 7. Tested SF error, mean wavelength and the SF calculated with the tested mean wavelength.
    T (°C)kλ (V/nm2)mλ0 (V/m)R2
    −40.27.300927×1080.0022210.9991
    −29.77.814259×1080.0022020.9993
    −20.58.766196×1080.0021760.9996
    −9.49.333737×1080.0021560.9992
    0.81.009304×1070.0021330.9995
    10.41.078659×1070.0021100.9996
    20.41.156246×1070.0020870.9994
    29.81.238980×1070.0020630.9997
    40.51.307796×1070.0020410.9993
    50.31.381143×1070.0020180.9995
    60.71.446607×1070.0019960.9994
    70.41.529232×1070.0019730.9993
    Table 1. Model Parameters with Linear Fitting (m=kλλ+mλ0)
    λ (nm)kT (V/(nm·°C))mT0 (V/m)R2
    1528.3821.1515618×1060.00228680.9993
    1533.4621.1477535×1060.00228730.9997
    1538.5851.1439462×1060.00228780.9994
    1543.3421.1404391×1060.00228830.9996
    1548.5131.1366294×1060.00228880.9995
    1553.3411.1331159×1060.00228930.9997
    1558.5861.1293042×1060.00228980.9998
    1563.4521.1258004×1060.00229030.9995
    1567.9531.1225748×1060.00229080.9992
    Table 2. Model Parameters with Linear Fitting (m=kTT+mT0)