    JINHUA BAO, XINJIE MAO, HAIRONG WANG, JI C. HE, FAN LU. ZERNIKE ASTIGMATISM AND VISUAL PERFORMANCE IN MYOPIC EYES BY RIGID GAS PERMEABLE CONTACT LENSES WEAR[J]. Journal of Innovative Optical Health Sciences, 2012, 5(3): 1250013 Copy Citation Text show less

    Abstract

    Purpose: To investigate the effects of rigid-gas-permeable contact lens (RGP-CL) wear on Zernike astigmatism and visual performance in myopic eyes. Methods: A wavefront sensor was used to evaluate Zernike astigmatism for 21 eyes with minimum astigmatism and 18 eyes with moderate astigmatism under three different modes of refractive correction: the RGP-CL, spectacle lens correcting spherical equivalent (SL) and spectacle lens fully correcting spherical error and astigmatism (fSL). Contrast visual acuity was assessed with a VA tester at four contrast levels and two luminance backgrounds. Results: Compared to the SL wear, RGP-CL wear changed the main axis astigmatism (Z22 ) from -0.09 ± 0.34 to 0.34±0.22 for the minimum astigmatism group, while the contrast VA was improved about 0.05 LogMAR (F = 8.06, p < 0.01). For the group with moderate astigmatism, significant reduction in Z22 was found for both fSL wear (t = 4.78, p < 0.001) and RGP-CL wear (t = 6.29, p < 0.0001). The changes in astigmatism were significantly correlated between the fSL and RGP-CL wears (r = 0.897, p < 0.0001 for Z-22 ; and r = 0.643, p = 0.004 for Z22) . Contrast VA was significantly improved for both fSL and RGP-CL wears and the improvements were significantly correlated between each other for all four contrast levels and two backgrounds. Conclusion: RGP-CL wear induces astigmatism for the eyes with minor astigmatism probably due to a correction of corneal astigmatism and thus a manifesting of the lens astigmatism. For the astigmatic eyes, RGP-CL wear has similar effect on correcting astigmatism as the spectacle lens wear with spherical-cylinder correction and also produces similar visual improvement.
    JINHUA BAO, XINJIE MAO, HAIRONG WANG, JI C. HE, FAN LU. ZERNIKE ASTIGMATISM AND VISUAL PERFORMANCE IN MYOPIC EYES BY RIGID GAS PERMEABLE CONTACT LENSES WEAR[J]. Journal of Innovative Optical Health Sciences, 2012, 5(3): 1250013
    Download Citation