• Infrared and Laser Engineering
  • Vol. 50, Issue 10, 20210043 (2021)
Lijing Cai1, Kailai Zhou1, Guizhu Shen2, Yiyang Yao2..., Lanxin Qiu2, Chongde Zi1 and Xun Cao1|Show fewer author(s)
Author Affiliations
  • 1School of Electronic Science and Engineering, Nanjing University, Nanjing 210123, China
  • 2Information & Telecommunication Branch, State Grid Zhejiang Electric Power Co., LTD., Hangzhou 310020, China
  • show less
    DOI: 10.3788/IRLA20210043 Cite this Article
    Lijing Cai, Kailai Zhou, Guizhu Shen, Yiyang Yao, Lanxin Qiu, Chongde Zi, Xun Cao. High-precision temperature measurement and calibration technology of infrared thermal imager[J]. Infrared and Laser Engineering, 2021, 50(10): 20210043 Copy Citation Text show less
    Schematic diagram of radiation received by infrared thermal imager
    Fig. 1. Schematic diagram of radiation received by infrared thermal imager
    Temperature measurement calibration device
    Fig. 2. Temperature measurement calibration device
    Blackbody temperature measurement curve of 38 ℃ after calibration with baffle
    Fig. 3. Blackbody temperature measurement curve of 38 ℃ after calibration with baffle
    Comparison of effects before and after temperature measurement calibration
    Fig. 4. Comparison of effects before and after temperature measurement calibration
    Fitting results of temperature measurement
    Fig. 5. Fitting results of temperature measurement
    Temperature measurement results before and after temperature compensation
    Fig. 6. Temperature measurement results before and after temperature compensation
    Fitting curve of temperature compensation
    Fig. 7. Fitting curve of temperature compensation
    Temperature curve after calibrating and correcting with compensation
    Fig. 8. Temperature curve after calibrating and correcting with compensation
    Relative error of temperature curves
    Fig. 9. Relative error of temperature curves
    DeviceBefore calibrationAfter calibration
    Blackbody1 (33 ℃)2.85%0.12%
    Blackbody2 (36 ℃)0.97%0.28%
    Blackbody3 (37 ℃)0.49%0.20%
    Blackbody4 (38 ℃)0.50%0.29%
    Blackbody5 (42 ℃)1.45%0.69%
    Table 1. Comparison of relative errors before and after calibration of temperature measurement