• Infrared and Laser Engineering
  • Vol. 49, Issue 6, 20200034 (2020)
Li Hongmei1、2, Cao Yiping1、*, Wang Yapin1, Wang Lu1, Li Chengmeng1, An Haihua1, and Xu Cai1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/irla20200034 Cite this Article
    Li Hongmei, Cao Yiping, Wang Yapin, Wang Lu, Li Chengmeng, An Haihua, Xu Cai. Single-shot 3D measurement using grayscale expanded composited grating[J]. Infrared and Laser Engineering, 2020, 49(6): 20200034 Copy Citation Text show less
    Procedure of orthogonal composite grating
    Fig. 1. Procedure of orthogonal composite grating
    Procedure of OCGGE
    Fig. 2. Procedure of OCGGE
    Experimental contrast between OCG and OCGGE. (a), (f) Deformed pattern of OCG and OCGGE; (b), (g) spectrum distribution of OCG and OCGGE; (c), (d), (e) OCG cutaway views at column 512 of the deformed phase shifting fringe patterns extracting from filter1, filter2, filter3; (h), (i), (j) OCGGE cutaway views at column 512 of the deformed phase shifting fringe patterns extracting from filter4, filter5, filter6; (k) reconstructed result of OCG; (l) zoom in on the dashed box from Fig.3(k); (m) reconstructed result of OCGGE
    Fig. 3. Experimental contrast between OCG and OCGGE. (a), (f) Deformed pattern of OCG and OCGGE; (b), (g) spectrum distribution of OCG and OCGGE; (c), (d), (e) OCG cutaway views at column 512 of the deformed phase shifting fringe patterns extracting from filter1, filter2, filter3; (h), (i), (j) OCGGE cutaway views at column 512 of the deformed phase shifting fringe patterns extracting from filter4, filter5, filter6; (k) reconstructed result of OCG; (l) zoom in on the dashed box from Fig.3(k); (m) reconstructed result of OCGGE
    Comparison results between OCG, OCGGE and PMP. (a) Measured object; (b) deformed pattern of OCGGE; (c) reconstructed result with OCGGE; (d) cutaway view at column 476 with OCG, OCGGE and PMP; (e) magnified view of the dashed box from Fig. 4(d); (f) magnified view of the point line box from Fig. 4(d)
    Fig. 4. Comparison results between OCG, OCGGE and PMP. (a) Measured object; (b) deformed pattern of OCGGE; (c) reconstructed result with OCGGE; (d) cutaway view at column 476 with OCG, OCGGE and PMP; (e) magnified view of the dashed box from Fig. 4(d); (f) magnified view of the point line box from Fig. 4(d)
    Li Hongmei, Cao Yiping, Wang Yapin, Wang Lu, Li Chengmeng, An Haihua, Xu Cai. Single-shot 3D measurement using grayscale expanded composited grating[J]. Infrared and Laser Engineering, 2020, 49(6): 20200034
    Download Citation