• Laser & Optoelectronics Progress
  • Vol. 49, Issue 8, 81404 (2012)
Guo Ruhai*, Sun Tao, and Wang Bing
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/lop49.081404 Cite this Article Set citation alerts
    Guo Ruhai, Sun Tao, Wang Bing. Method of Pointing Measurement Based on Infrared Image Processing for Mid-Infrared Laser[J]. Laser & Optoelectronics Progress, 2012, 49(8): 81404 Copy Citation Text show less

    Abstract

    The directed infrared projecting device based on mid-infrared laser has become more important because the mid-infrared (3~5 μm) detectors have been widely applied in the military field. The beam pointing stability is the key parameter for such application. The beam pointing measurement is conducted for an optical parameter oscillation (OPO) mid-infrared laser. The mid-infrared imaging system, image edge extraction algorithm and threshold algorithm are adopted to obtain the pointing data of this mid-infrared laser. The experimental results show that the maximum pointing error is 1.1 mrad and the average is 0.3 mrad at room temperature. The main reason is that the temperature control system for laser diode (LD) is not perfect and it may be improved further. The measurement results can provide references for the investigation, beam shaping, pointing measurement and stability techniques of mid-infrared lasers.
    Guo Ruhai, Sun Tao, Wang Bing. Method of Pointing Measurement Based on Infrared Image Processing for Mid-Infrared Laser[J]. Laser & Optoelectronics Progress, 2012, 49(8): 81404
    Download Citation