• Laser & Optoelectronics Progress
  • Vol. 59, Issue 13, 1328001 (2022)
Weihua Shi*, Rongqiu Mu, and Ling Zhang
Author Affiliations
  • School of Electronic and Optical Engineering, School of Microelectronics, Nanjing University of Posts and Telecommunications, Nanjing 210023, Jiangsu , China
  • show less
    DOI: 10.3788/LOP202259.1328001 Cite this Article Set citation alerts
    Weihua Shi, Rongqiu Mu, Ling Zhang. Biological Mass Concentration and Temperature Dual Parametric Sensing Based on Photonic Crystal Fiber[J]. Laser & Optoelectronics Progress, 2022, 59(13): 1328001 Copy Citation Text show less
    Structure of the sensor. (a) Cross-sectional view of the SPR-based biointegrated sensor; (b) schematic diagram of the stacking fabrication method
    Fig. 1. Structure of the sensor. (a) Cross-sectional view of the SPR-based biointegrated sensor; (b) schematic diagram of the stacking fabrication method
    Resonance loss curve of the sensor when the temperature is 20 ℃
    Fig. 2. Resonance loss curve of the sensor when the temperature is 20 ℃
    Sensing characteristic curve of the SPR
    Fig. 3. Sensing characteristic curve of the SPR
    Refractive index characteristic curve of core guided mode at T=20 ℃. (a) Characteristic diagram of core guided mode loss under different mass concentrations; (b) change point and linear fitting diagram of resonance wavelength and mass concentration
    Fig. 4. Refractive index characteristic curve of core guided mode at T=20 ℃. (a) Characteristic diagram of core guided mode loss under different mass concentrations; (b) change point and linear fitting diagram of resonance wavelength and mass concentration
    Temperature characteristic curve of core guided mode when n=1.37. (a) Resonance loss diagram at different temperatures; (b) change point and linear fitting diagram of resonance wavelength and temperature
    Fig. 5. Temperature characteristic curve of core guided mode when n=1.37. (a) Resonance loss diagram at different temperatures; (b) change point and linear fitting diagram of resonance wavelength and temperature
    Sensor typeDetectionRangeSensitivityReference
    Ours

    mass concentration

    RIU

    temperature

    34.6‒186.7 mg/mL(1.34‒1.37)20‒45 ℃5.44 nm/mg·mL-1(12667 nm/RIU)17.3 nm/℃-
    SPR PCF sensor based on gold-PDMS coatingtemperature22‒47 ℃-8.18 nm/℃14
    SPR PCF biosensorDANCE1.33‒1.539000 nm/RIU15
    SPR PCF biosensor based onTiO2 filmRIU1.33‒1.384200 nm/RIU16
    SPR PCF biosensor based on gold filmRIU1.33‒1.4012000 nm/RIU17
    Table 1. Performance comparison of different sensors
    Weihua Shi, Rongqiu Mu, Ling Zhang. Biological Mass Concentration and Temperature Dual Parametric Sensing Based on Photonic Crystal Fiber[J]. Laser & Optoelectronics Progress, 2022, 59(13): 1328001
    Download Citation