    Process of establishing non-square trace map. (a) Frog trace of square SHG configuration; (b) trace generated by reducing sampling bandwidth of trace frequency axis; (c) trace generated by reducing sampling times of trace delay axis; (d) trace generated by increasing sampling frequency of trace frequency axis
    Fig. 1. Process of establishing non-square trace map. (a) Frog trace of square SHG configuration; (b) trace generated by reducing sampling bandwidth of trace frequency axis; (c) trace generated by reducing sampling times of trace delay axis; (d) trace generated by increasing sampling frequency of trace frequency axis
    Reconstruction of analog pulses with non-square trace. (a) FROG trace of square SHG configuration; (b) FROG trace of non-square SHG configuration of 168×14 size; (c)--(d) amplitude distribution and phase distribution of Fig. (a) and Fig. (b); (e) FROG trace of square PG configuration; (f) FROG trace of non-square PG configuration of 168×12 size; (g)--(h) amplitude distribution and phase distribution of Fig. (e) and Fig. (f); (i) FROG trace of square XPM configuration; (j) FROG trace of non-square XPM configuration of 168×8 size; (k)--(l) amplitude distribution and phase distribution of Fig. (i) and Fig. (j)
    Fig. 2. Reconstruction of analog pulses with non-square trace. (a) FROG trace of square SHG configuration; (b) FROG trace of non-square SHG configuration of 168×14 size; (c)--(d) amplitude distribution and phase distribution of Fig. (a) and Fig. (b); (e) FROG trace of square PG configuration; (f) FROG trace of non-square PG configuration of 168×12 size; (g)--(h) amplitude distribution and phase distribution of Fig. (e) and Fig. (f); (i) FROG trace of square XPM configuration; (j) FROG trace of non-square XPM configuration of 168×8 size; (k)--(l) amplitude distribution and phase distribution of Fig. (i) and Fig. (j)
    Reconstruction of aperiodic scale experimental pulses from non-square traces. (a) FROG trace of square SHG configuration; (b) FROG trace of non-square SHG configuration of 168×14 size; (c)--(d) amplitude distribution and phase distribution of Fig. (a) and Fig. (b); (e) FROG trace of square PG configuration; (f) FROG trace of non-square PG configuration of 168×12 size; (g)--(h) amplitude distribution and phase distribution of Fig. (e) and Fig. (f); (i) FROG trace of square XPM configuration; (j) FROG trace of non-square XPM configuration of 168× 8 size; (k)--(l) amplitude distribution and phase distribution of Fig. (i) and Fig. (j)
    Fig. 3. Reconstruction of aperiodic scale experimental pulses from non-square traces. (a) FROG trace of square SHG configuration; (b) FROG trace of non-square SHG configuration of 168×14 size; (c)--(d) amplitude distribution and phase distribution of Fig. (a) and Fig. (b); (e) FROG trace of square PG configuration; (f) FROG trace of non-square PG configuration of 168×12 size; (g)--(h) amplitude distribution and phase distribution of Fig. (e) and Fig. (f); (i) FROG trace of square XPM configuration; (j) FROG trace of non-square XPM configuration of 168× 8 size; (k)--(l) amplitude distribution and phase distribution of Fig. (i) and Fig. (j)
    F_LPFF_USD_DSShapeθ
    1/3×1/3×84×420.034±0.003
    1/6×84×210.065±0.005
    1/8.5×84×150.091±0.005
    1/9×84×140.121±0.005
    1/3×168×420.025±0.005
    1/6×168×210.060±0.004
    1/8.5×168×150.072±0.008
    1/9×168×140.098±0.004
    1/10×168×130.125±0.005
    Table 1. Pulse reconstruction results of non-square trace based on SHG configuration
    F_LPFF_USD_DSShapeθ
    1/3×1/3×84×420.025±0.003
    1/6×84×210.055±0.006
    1/10×84×130.097±0.007
    1/10.5×84×120.118±0.006
    1/3×168×420.023±0.005
    1/6×168×210.053±0.003
    1/10×168×130.088±0.006
    1/10.5×168×120.099±0.004
    1/11.5×168×110.121±0.005
    Table 2. Pulse reconstruction results of non-square trace based on PG configuration
    F_LPFF_USD_DSMesh sizeθ
    1/3×1/3×84×420.020±0.002
    1/6×84×210.051±0.003
    1/14×84×90.096±0.006
    1/16×84×80.123±0.005
    1/3×168×420.018±0.002
    1/6×168×210.043±0.003
    1/14×168×90.079±0.007
    1/16×168×80.093±0.006
    1/18×168×70.116±0.007
    Table 3. Pulse reconstruction results of non-square trace based on XPM configuration