• Chinese Optics Letters
  • Vol. 19, Issue 5, 052703 (2021)
Yajun Wang1、2, Yuhang Tian1, Xiaocong Sun1, Long Tian1、2, and Yaohui Zheng1、2、*
Author Affiliations
  • 1State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Opto-Electronics, Shanxi University, Taiyuan 030006, China
  • 2Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, China
  • show less
    DOI: 10.3788/COL202119.052703 Cite this Article Set citation alerts
    Yajun Wang, Yuhang Tian, Xiaocong Sun, Long Tian, Yaohui Zheng. Noise transfer of pump field noise with analysis frequency in a broadband parametric downconversion process[J]. Chinese Optics Letters, 2021, 19(5): 052703 Copy Citation Text show less
    Configuration of the squeezed state generation. FI, Faraday isolator; MC, mode cleaner; SHG, second harmonic generation; OPO, optical parametric oscillator; OPA, optical parametric amplifier; PBS, polarization beam splitter; DBS, dichroic beam splitter; EOM, electro-optical modulator; EOAM, electro-optic amplitude modulator; PZT, piezoelectric transducer; PD, photodetector; BHD, balanced homodyne detection; SHD: self-homodyne detection.
    Fig. 1. Configuration of the squeezed state generation. FI, Faraday isolator; MC, mode cleaner; SHG, second harmonic generation; OPO, optical parametric oscillator; OPA, optical parametric amplifier; PBS, polarization beam splitter; DBS, dichroic beam splitter; EOM, electro-optical modulator; EOAM, electro-optic amplitude modulator; PZT, piezoelectric transducer; PD, photodetector; BHD, balanced homodyne detection; SHD: self-homodyne detection.
    Experimental results of the white noise direct output from the function generator and quadrature amplitude variances, with frequency for different pump beam noises, which are measured with the self-homodyne method. Case (a), without amplitude modulation; an amplitude modulation of 400 mV for case (b), 800 mV for case (c), and 1600 mV for case (d). RBW: 300 kHz and VBW: 200 Hz.
    Fig. 2. Experimental results of the white noise direct output from the function generator and quadrature amplitude variances, with frequency for different pump beam noises, which are measured with the self-homodyne method. Case (a), without amplitude modulation; an amplitude modulation of 400 mV for case (b), 800 mV for case (c), and 1600 mV for case (d). RBW: 300 kHz and VBW: 200 Hz.
    Experimental results of the amplitude squeezed quadrature noise with the variation of pump intensity noise at the Fourier frequency from 2 MHz to 30 MHz. RBW: 300 kHz and VBW: 200 Hz.
    Fig. 3. Experimental results of the amplitude squeezed quadrature noise with the variation of pump intensity noise at the Fourier frequency from 2 MHz to 30 MHz. RBW: 300 kHz and VBW: 200 Hz.
    Yajun Wang, Yuhang Tian, Xiaocong Sun, Long Tian, Yaohui Zheng. Noise transfer of pump field noise with analysis frequency in a broadband parametric downconversion process[J]. Chinese Optics Letters, 2021, 19(5): 052703