• Opto-Electronic Engineering
  • Vol. 37, Issue 10, 64 (2010)
LI Shun1、2, GONG Yan1, and ZHANG Wei1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article
    LI Shun, GONG Yan, ZHANG Wei. Image Quality Evaluation of Grazing Incidence Optical System[J]. Opto-Electronic Engineering, 2010, 37(10): 64 Copy Citation Text show less
    References

    [1] Lemen James R,Dexter Duncan,Christopher Edwards,et al. The Solar X-ray Imager for GOES [J]. Proc. of SPIE(S0277-786X),2004,5171:65-76.

    [2] CHEN Bo,NI Qi-liang,CAO Ji-hong,et al. Development of a space soft X-ray and EUV normal incidence telescope [J].Optics and Precision Engineering ,2003,11(4):315-319.

    [3] CAO Zhi-yu,LU Guo-ping,LI Bao-quan. The Technique of Space Solar X-Ray Telescope [J]. Aerospace Shanghai,2004(2):40-44.

    [4] GONG Yan. Testing system for performance of EUV solar telescope [J]. Optics and Precision Engineering,2006,14(6):969-973.

    [5] Mangus J D,Underwood J H. Optical design of a glancing incidence x-ray telescope [J]. Appl. Opt(S0003-6935),1969,8(1):95-102.

    [6] Van Speybroeck L P,Chase R C. Design parameters of paraboloid-hyperboloid telescopes for x-ray astronomy [J]. Appl. Opt(S0003-6935),1972,11(2):440-445.

    [7] KUANG Yu-guang. Optical design of x-ray imaging telescope [J]. Acta Optica Sinica,1981,1(3):239-246.

    [8] Harvey James E,Krywonos Andrey,Thompson Patrick L,et al. Grazing-incidence hyperboloid-hyperboloid designs for wide-field x-ray imaging applications [J]. Appl. Opt(S0003-6935),2001,40(1):136-144.

    [9] Saha Timo T,Zhang William. Equal-curvature grazing-incidence x-ray telescopes [J]. Appl. Opt(S0003-6935),2003,42(22):4599-4605.

    [10] CHEN Bo,CHEN Shu-yan,GONG Yan. Design of a complex space soft X-ray and EUV telescope [J]. Optical Technique,2004,30(2):242-244.

    [11] Werner W. Imaging properties of Wolter I type x-ray telescopes [J]. Appl.Opt(S0003-6935),1977,16(3):764-773.

    [12] Nariai Kyoji. Geometric aberration of a generalized Wolter type I telescope [J]. Appl.Opt(S0003-6935),1987,26(20):4428-4432.

    [13] Saha Timo T. Aberrations for grazing incidence telescopes [J]. Appl.Opt(S0003-6935),1988,27(8):1492-1498.

    [14] LI Shun,GONG Yan. Design of Grazing Incidence Optical System [J]. Acta Optica Sinica,2009,29(8):2276-2281.

    [15] ZHANG Wen-jing,LIU Wen-guang,Liu Zhe-jin. Dynamic data exchange between Zemax and Matlab [J]. Journal of AppliedOptics,2008,29(4):553-556.

    [16] LIU Ri-sheng,GAO Wei-hua. Matlab’s dynamic data exchange and it’s application [J]. Measurement & Control Technology,2001,20(6):39-40.

    LI Shun, GONG Yan, ZHANG Wei. Image Quality Evaluation of Grazing Incidence Optical System[J]. Opto-Electronic Engineering, 2010, 37(10): 64
    Download Citation