[1] A Hirata, Y L Diao, T Onishi et al. Assessment of human exposure to electromagnetic fields: review and future directions. IEEE Transactions on Electromagnetic Compatibility, 63, 1619-1630(2021).
[2] J Kim, K Lee, B Kim et al. Numerical and experimental assessments of focused microwave thermotherapy system at 925 MHz. ETRI Journal, 41, 850-862(2019).
[3] Yanping LIN, Mai LU, Xi LIU et al. Study on electromagnetic field and temperature field distribution in animal model during magnetic induction hyperthermia. Journal of Biomedical Engineering Research, 38, 16-21(2019).
[4] J Chakarothai, J J Shi, J Q Wang et al. Numerical techniques for SAR assessment of small animals in reverberation chamber. IEEE Electromagnetic Compatibility Magazine, 4, 57-66(2015).
[5] A Bamba, W Joseph, G Vermeeren et al. A formula for human average whole-body SARwb under diffuse fields exposure in the GHz region. Physics in Medicine and Biology, 59, 7435-7456(2014).
[6] J Chakarothai, K Wake, S Watanabe. Convergence of a single-frequency FDTD solution in numerical dosimetry. IEEE Transactions on Microwave Theory and Techniques, 64, 707-714(2016).
[7] Jiakai TONG, Hongxin QI, Xianghui WANG et al. Simulation calculation of electric field distribution in rats irradiated using broadband electromagnetic pulse. Journal of Radiation Research and Radiation Processing, 40, 020702(2022).
[8] E A Rashed, J Gomez-Tames, A Hirata. Human head skin thickness modeling for electromagnetic dosimetry. IEEE Access, 7, 46176-46186.
[9] S Dahdouh, N Varsier, M A Nunez Ochoa et al. Infants and young children modeling method for numerical dosimetry studies: application to plane wave exposure. Physics in Medicine and Biology, 61, 1500-1514(2016).
[10] N Kuster, V B Torres, N Nikoloski et al. Methodology of detailed dosimetry and treatment of uncertainty and variations for in vivo studies. Bioelectromagnetics, 27, 378-391(2006).
[11] P Gajsek, W D Hurt, J M Ziriax et al. Parametric dependence of SAR on permittivity values in a man model. IEEE Transactions on Biomedical Engineering, 48, 1169-1177(2001).
[12] E Conil, A Hadjem, A Gati et al. Influence of plane-wave incidence angle on whole body and local exposure at 2100 MHz. IEEE Transactions on Electromagnetic Compatibility, 53, 48-52(2011).
[13] S Iskra, R McKenzie, I Cosic. Factors influencing uncertainty in measurement of electric fields close to the body in personal RF dosimetry. Radiation Protection Dosimetry, 140, 25-33(2010).
[14] X H Wang, C J Xia, L Lu et al. Electromagnetic exposure dosimetry study on two free rats at 1.8 GHz via numerical simulation. Frontiers in Public Health, 9, 721166(2021).
[15] K K Kesari, J Behari, S Kumar. Mutagenic response of 2.45 GHz radiation exposure on rat brain. International Journal of Radiation Biology, 86, 334-343(2010).
[16] R Kitchen. RF andmicrowave radiation safety, 60-62(2001).
[17] J C Lin. Electromagnetic fields in biological systems, 24(2012).