• Acta Optica Sinica
  • Vol. 31, Issue 11, 1115001 (2011)
Wang Shun*, Xu Jingzhu, Zhang Yixin, Zhang Xuping, and Xie Fei
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201131.1115001 Cite this Article Set citation alerts
    Wang Shun, Xu Jingzhu, Zhang Yixin, Zhang Xuping, Xie Fei. Reliability Evaluation Method and Application for Light-Stripe-Center Extraction[J]. Acta Optica Sinica, 2011, 31(11): 1115001 Copy Citation Text show less
    References

    [1] Sun Changku, Ye Shenghua. Laser Measurement Technology[M]. Tianjing: Tianjing University Press, 2001. 129~139

    [2] Wu Jianbo, Cui Zhen, Zhao Hong et al.. An adaptive threshold method for light-knife center acquisition[J]. Semiconductor Optoelectronics, 2001, 22(1): 62~64

    [3] Wu Qingyang, Su Xianyu, Li Jingzhen et al.. A new method for extracting the centre-line of line structure light-stripe[J]. J. Sichuan University (Engineering Science Edition), 2007, 39(4): 151~155

    [4] Li Zhongwei, Wang Congjun, Shi Yusheng. An algorithm for detecting center of structured light stripe combining gradient sharpening with barycenter method[J]. J. Image and Graphics, 2008, 13(1): 64~68

    [5] Hu Bin, Li Dehua, Jin Gang et al.. New method for obtaining the center of structured light stripe by direction template[J]. Computer Engineering and Applications, 2002, 38(11): 59~60

    [6] He Zhonghai, Wang Baoguang, Liao Yibai et al.. Subpixel algorithm using a curve fitting method [J]. Chinese J. Scientific Instrument, 2003, 24(2): 195~197

    [7] Sui Liansheng, Li Bing, Jiang Zhuangde. Research on method of laser-knife center position etracting based on NURBS interpolation[J]. Chinese J. Lasers, 2003, 30(10): 933~937

    [8] C. Steger. An unbiased detector of curvilinear structures[J ] . IEEE Transactions on Pattern Analysis and Machine Intelligence, 1998, 20(2): 113~125

    [9] Zhou Fuqiang, Chen Qiang, Zhang Guangjun. Composite image processing for center extraction of structured light stripe[J]. J. Optoelectronics· Laser, 2008, 19(11): 1534~1537

    [10] Zhang Yixin, Wang Shun, Zhang Xuping. Defocused blur image restoration in large scale 3D vision measurement[J]. Chinese J. Scientific Instrument, 2010, 31(12): 1~6

    [11] J. W. Weng, P. Cohen, M. Herniou. Camera calibration with distortion models and accuracy evaluation[J]. Transactions on Pattern Analysis and Machine Intelligence, 1992, 14(10): 965~980

    [12] R. Y. Tsai. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV camera and lenses[J]. IEEE J. Robotics and Automation, 1987, 3(4): 323~344

    [13] Zhu Jigui, Li Yanjun, Ye Shenghua et al.. Study on single camera simulating stereo vision measurement technology [J]. Acta Optica Sinica, 2005, 25(7): 943~948

    [14] Wang Baoguang, He ZhongHai, Chen Lincai et al.. Model and performance analysis of structured light sensor [J]. Acta Optica Sinica, 2002, 22(4): 481~484

    [15] Zhang Shunde, Lu Bingheng, Ding Yucheng. Research on light-knife propagated by reflection of Gaussian light beams at cylinder [J]. Chinese J. Lasers, 2001, 28(2): 133~136

    [16] Sun Jiaguang. Computer Graphics (Third Edition)[M]. Beijing: Tsinghua University Press, 1998. 506~508

    [17] Kazuya Yonemoto. CCD/CMOS Image Sensor Foundation and Application[M]. Chen Rongting et al. Transl.. Beijing: Science Press, 2006. 23~69

    CLP Journals

    [1] Taotao Li, Feng Yang, Ce Li, Liang Fang. Exposure Time Optimization for Line Structured Light Sensor Based on Light Stripe Reliability Evaluation[J]. Acta Optica Sinica, 2018, 38(1): 0112005

    [2] Chai Yuting, Wang Zhao, Gao Jianmin, Huang Junhui. Highlight Removal Based on Frequency-Domain Filtering[J]. Laser & Optoelectronics Progress, 2013, 50(5): 51205

    [3] Wang Haiyong, Zhou Wenrui, Zhao Yanwu. Error Analysis and Applicability Study on Simplified Gaussian Gray Diffusion Model[J]. Acta Optica Sinica, 2012, 32(7): 711002

    [4] Liu Zhen, Li Sheng, Feng Chang. Laser Stripe Center Extraction Based on Cross-Correlation Algorithm[J]. Chinese Journal of Lasers, 2013, 40(5): 508004

    [5] Li Yunpeng, Tian Qingguo, Zhang Xiangyu, Wei Yaolin, Ge Baozhen. Multi-Sensor Synchronous Calibration Method for Line Laser Human-Body 3D Scanner[J]. Chinese Journal of Lasers, 2013, 40(10): 1008006

    Wang Shun, Xu Jingzhu, Zhang Yixin, Zhang Xuping, Xie Fei. Reliability Evaluation Method and Application for Light-Stripe-Center Extraction[J]. Acta Optica Sinica, 2011, 31(11): 1115001
    Download Citation