• Acta Optica Sinica
  • Vol. 33, Issue 8, 812004 (2013)
Zhang Yanna*, Zheng Xiaobing, Li Jianjun, and Zhang Wei
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201333.0812004 Cite this Article Set citation alerts
    Zhang Yanna, Zheng Xiaobing, Li Jianjun, Zhang Wei. Research on System Level Calibration Method of Multi-Band Filter Radiometer[J]. Acta Optica Sinica, 2013, 33(8): 812004 Copy Citation Text show less
    References

    [1] H W Yoon, C E Gibson. Comparison of the absolute detector-based spectral radiance assignment with the current NIST-assigned spectral radiance of tungsten strip lamps[J]. Metrologia, 2000, 37(5): 429-432.

    [2] Li Youping, Yu Bingxi, Wang Yupeng, et al.. Measurement chain of influence quanties and uncertainty of radiometric calibration for imaging spectrometer [J]. Optics and Precision Engineering, 2006, 14(5): 822-828.

    [3] Song Zongxi, Zhao Baochang, Gao Wei, et al.. Focal plane design of Chang′e-1 satellite CCD stereo-camera and laboratory radiation calibration[J]. Acta Optica Sinica, 2010, 30(12): 3508-3514.

    [4] Yang Benyong, Zhang Liming, Chen Hongyao, et al.. System design of the integrating sphere used for on-board calibration of visible-SWIR hyperspectral remote sensors [J]. Acta Optica Sinica, 2009, 29(12): 3545-3550.

    [5] S W Brown, G P Eppeldauer, K R Lykke. Facility for spectral irradiance and radiance responsivity calibrations using uniform sources[J]. Appl Opt, 2006, 45(32): 8218-8237.

    [6] B C Johnson, S W Brown, G P Eppeldauer, et al.. System-level calibration of a transfer radiometer used to validate EOS radiance scales [J]. International J Remote Sensing, 2003, 24(2): 339-356.

    [7] J J Butler, R A Barnes. The use of transfer radiometers in validating the visible to shortwave infrared calibrations of radiance sources used by instruments in NASA′s earth observing system [J]. Metrologia, 2003, 40(1): S70-S77.

    [8] Zou Peng, Zheng Xiaobing, Wu Haoyu, et al.. Development of multi-band radiance standard transfer detector[J]. Acta Optica Sinica, 2011, 31(4): 0404002.

    [9] Li Zhaozhou. Studies of Highly Accurate Radiometric Calibration and Application Based on Radiance Standard Detector [D]. Hefei: Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, 2005.

    [10] Xu Qiuyun, Zheng Xiaobing, Li Jianjun, et al.. Development of laser illuminated integrating sphere source[J]. Optics and Precision Engineering, 2009, 17(4): 738-744.

    [11] Jin Weiqi, Hu Weijie. Radiometric Photometric Chromaticity and Its Measurement[M]. Beijing: Beijing Institute of Technology Press, 2006. 7-8.

    [12] Li Jianjun, Zheng Xiaobing, Lu Yunjun, et al.. Accurate calibration of the spectral responsivity of silicon trap detectors between 350 nm and 1064 nm [J]. Acta Physica Sinica, 2009, 58(9): 6273-6278.

    [13] Barry N Taylor, Chris E Kuyatt. Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results. NIST Technical Note 1297[M]. Darby: DIANE Publishing, 1994.

    [14] B N Holben, T F Eck, I Slutsker, et al.. AERONET—federated instrument network and data archive for aerosol characterization [J]. Remote Sensing of Environment, 1998, 66(1): 1-16.

    [15] Zhengqiang Li, Luc Blarel, Thierry Podrin, et al.. Transferring the calibration of direct solar irradiance to diffuse-sky radiance measurements for CIMEL sun-sky radiometers [J]. Appl Opt, 2008, 47(10): 1368-1377.

    [16] Nordine Souaidia, Christophe Pietras, Giulietta Fargion, et al.. Comparison of laser-based and conventional calibrations of sun photometers[C]. SPIE , 2003, 5155: 61-72.

    CLP Journals

    [1] Zhang Zhao, Wan Zhi, Sun Jingxu, Liu Zexun, Ren Jianwei, Ren Jianyue. Development and Calibration of Dual-Waveband Infrared Radiometer for Jones Calibration Method[J]. Acta Optica Sinica, 2016, 36(6): 623002

    [2] Sun Zhiyuan, Chang Songtao, Zhu Wei. Radiation Calibration Method for Infrared System with Large Aperture and Broad Dynamic Range[J]. Acta Optica Sinica, 2014, 34(7): 712006

    [3] Liu Yingqi, Liu Xiangyi. Research on Technology of Ground-Based Infrared Radiation Feature Measurement for Space Target[J]. Acta Optica Sinica, 2014, 34(5): 512003

    [4] Yang Xiaohu, Wang Shurong, Huang Yu. Research on Radiation Characteristic of the Multi-Azimuth/Multi-Waveband Earth Limb Ultraviolet Imager[J]. Acta Optica Sinica, 2014, 34(8): 801001

    Zhang Yanna, Zheng Xiaobing, Li Jianjun, Zhang Wei. Research on System Level Calibration Method of Multi-Band Filter Radiometer[J]. Acta Optica Sinica, 2013, 33(8): 812004
    Download Citation