• Acta Optica Sinica
  • Vol. 33, Issue 1, 112008 (2013)
Xing Hui*, Jiao Wenchun, and Wang Yun
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201333.0112008 Cite this Article Set citation alerts
    Xing Hui, Jiao Wenchun, Wang Yun. Method to Elicit the Boresight of Infrared Cryogenic Camera[J]. Acta Optica Sinica, 2013, 33(1): 112008 Copy Citation Text show less
    References

    [1] Shen Mangzuo, Ma Wenli, Liao Sheng et al.. Development of a cryogenic optical system[J]. Acta Optica Sinica, 2001, 21(2): 202~205

    [2] Yang Zaihua, Sun Gang, Liu Jianxin. Measurement of orientation of optic axis of space camera with theodolite[J]. Spacecraft Environment Engineering, 2010, 27(1): 92~94

    [3] Shen Zhaoxin, Chen Xiaohui. A technology to get coordinate-system of cube-prism in electron-theodolite surveying system[J]. J. Astronautic Metrology and Mearurement, 2006, 26(4): 73~75

    [4] John Troll, Patrick Thompson, David Humm. Boresight and gimbal axis alignment for the CRISM instrument[C]. SPIE, 2005, 5877: 58770A

    [5] Young-Jin Lee, Alper Yilmaz. Boresight calibration of the aerial multi-head camera system[C]. SPIE, 2011, 8059: 805908

    [6] Andrzej W. Domanski, Daniel Budaszewski, Pawel Poziemski et al.. Method of optical axis determination in crystals by use of light depolarization measurements [C]. SPIE, 2007, 6616: 66161V

    [7] Liu Yong, Chen Xiaohui, Yin Qing et al.. Applications of three-dimension coordinate transform in space device′s geometry measurement[J]. Infrared and Laser Engineering, 2008, 37(s): 147~150

    [8] Wu Guodong, Song Dan. Calibration of mapping camera and cubic prism coordinate system[J]. Optics and Precision Engineering, 2007, 15(11): 1727~1730

    [9] Yang Zhen, Li Guangyun, Huang Guiping et al.. Research on attitude measurement method of cubic prism based on auto-collimation[J]. J. Astronautic Metrology and Mearurement, 2010, 30(2): 14~29

    [10] Gai Pengfei. Autocollimation method of theodolite or total station[J]. J. Geomatics Science and Technology, 2010, 27(3): 196~199

    [11] Liu Manlin, Hao Bin, Xiong Rensheng et al.. Visible light measurement television system design and sight line axial precision analysis[J]. Electro-Optic Technology Application, 2008, 23(6): 49~59

    [12] Zhang Man, Li Tao, Liu Jianxin. A new approach for precision measurements for a satellite under different pressure conditions[J]. Spacecraft Environment Engineering, 2006, 23(3): 165~174

    [13] Chen Jihua, Huang Jianbo, Mu Aiguo et al.. A novel method of auto-collimation by theodolite[J]. J. Zhengzhou Institute of Surveying and Mapping, 2006, 23(5): 338~344

    [14] Niu Lin, Chen Jianping, Tian Yi.The optimal choice of common points in three dimensional coordinate transformation[J]. Beijing Surveying and Mapping, 2007, (4): 9~11

    CLP Journals

    [1] Xing Hui. Method of Adjusting the Line Array Direction of the Time Delay Integration CCD[J]. Acta Optica Sinica, 2013, 33(9): 912006

    [2] Jia Xin, Fan Longfei, Miao Yang, Xing Hui, Zhong Hui. Modeling analysis of axis angle for nine-spectrum off-axis large-aperture assay camera[J]. Infrared and Laser Engineering, 2019, 48(4): 417007

    Xing Hui, Jiao Wenchun, Wang Yun. Method to Elicit the Boresight of Infrared Cryogenic Camera[J]. Acta Optica Sinica, 2013, 33(1): 112008
    Download Citation