• Laser & Optoelectronics Progress
  • Vol. 49, Issue 2, 20004 (2012)
Zhang Yu1、2、*, Tang Zhilie1, Wu Yongbo1, Xie Jiaxing2, Dai Fen2, and Zhao Wenfeng2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/lop49.020004 Cite this Article Set citation alerts
    Zhang Yu, Tang Zhilie, Wu Yongbo, Xie Jiaxing, Dai Fen, Zhao Wenfeng. Study of Various Photoacoustic Imaging Methods[J]. Laser & Optoelectronics Progress, 2012, 49(2): 20004 Copy Citation Text show less
    References

    [1] X. D. Wang, Y. J. Pang, G. Ku et al.. Three-dimensional laser-induced photoacoustic tomography of mouse brain with the skin and skull intact[J]. Opt. Lett., 2003, 28(19): 1739~1741

    [2] Y. Wang, D. Xing, Y. G. Zeng. Photoacoustic imaging with deconvolution algorithm[J]. Phys. Med. Biol., 2004, 49(14): 3117~3124

    [3] D. W. Yang, D. Xing, H. M. Gu et al.. Fast multielement phase-controlled photoacoustic imaging based on limited-field-filtered back-projection algorithm [J]. Appl. Phys. Lett., 2005, 87(19): 194101

    [4] R. A. Kruger, W. L. Kiser Jr., D. R. Reinecke et al.. Thermoacoustic computed tomography using a conventional linear transducer array [J ]. Med. Phys., 2003, 30(5): 856~860

    [5] A. A. Oraevsky, A. A. Karabutov, S. V. Solomatin et al.. Laser optoacoustic imaging of breast cancer in vivo[C]. SPIE, 2001, 4256: 352~363

    [6] B. Z. Yin, D. Xing, Y. Wang et al.. Fast photoacoustic imaging system based on 320-element linear transducer array [J]. Phys. Med. Biol., 2004, 49(7): 1339~1346

    [7] R. A. Kruger, P. Y. Liu, Y. C. Fang et al.. Photoacoustic ultrasound (PAUS)—reconstruction tomography[J]. Med. Phys., 1995, 22(10): 1605~1609

    [8] H. H. Barreu. Fundamentals of the Radon transform. in M. A. Viergever, A. Todd. Pokropek eds. Mathematics and Computer Science in Medical Imaging [M]. Berlin: Springer, 1998. 105~125

    [9] R. A. Kruger, S. Keith, J. W. L. Kiser. Thermoacoustic CT of the breast[C]. SPIE, 2003, 4682: 521~525

    [10] M. Xu, L. V. Wang. Time-domain reconstruction for thermoacoustic tomography in a spherical geometry[J]. IEEE Trans. Med. Imaging, 2002, 21(7): 814~822

    [11] X. D. Wang, Y. J. Pang, G. Ku et al.. Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain [J]. Nature Biotechnol., 2003, 21(7): 803~806

    [12] Y. Xu, L. H. Wang. Effects of acoustic heterogeneity on thermoacoustic tomography in the breast[J]. IEEE Trans. Ultrasonics Ferroelectrics and Frequency Control, 2003, 50(9): 1134~1146

    [13] G. Ku, X. D. Wang, G. Stoica et al.. Multiple-bandwidth photoacoustic tomography[J]. Phys. Med. Biol., 2004, 49(7): 1329~1338

    [14] K. P. Kstli, P. C. Beard. Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response[J]. Appl. Opt., 2003, 42(10): 1899~1908

    [15] Y. V. Zhulina. Optimal statistical approach to optoacoustic image reconstruction [J]. Appl. Opt., 2000, 39(32): 5971~5977

    [16] P. Y. Liu. The P-transform and photoacoustic imaging reconstruction [J]. Phys. Med. Biol., 1998, 43(3): 667~674

    [17] J. J. Niederhauser, M. Jaeger, M. Frenz. Real-time three-dimensional optoacoustic imaging using an acoustic lens system [J]. Appl. Phys. Lett., 2004, 85(5): 846~848

    [18] Chen Zhanxu, Tang Zhilie, Wan Wei et al.. Photoacoustic tomography imaging based on an acoustic lens imaging system [J]. Acta Physica Sinica, 2006, 55(8): 4365~4369

    [19] Zhanxu Chen, Zhilie Tang, Wei Wan et al.. Fast optoacoustic tomography imaging using an acoustic lens [C]. SPIE, 2006, 6047: 60470F

    [20] Yadong Wei, Zhilie Tang, Hanchao Zhang et al.. Photoacoustic tomography imaging using a 4f acoustic lens and peak-hold technology [J]. Opt. Express, 2008, 16(8): 5314~5319

    [21] Xian Chen, Zhilie Tang, Yongheng He et al.. Simultaneous photoacoustic imaging technique using an acoustic imaging lens [J]. J. Biomed. Opt., 2009, 14(3): 030511

    [22] J. K. Thomson, H. K. Wickramasinghe, E. A. Ash. A Fabry-Perot acoustic surface vibration detector-application to acoustic holography [J]. J. Phys. D: Appl. Phys., 1973, 6(6): 677~687

    [23] J.-P. Monchalin, R. Heon. Laser ultrasonic generation and optical detection with a confocal Fabry-Perot interferometer [J]. Mater. Trans. Eval., 1986, 44(10): 1231~1237

    [24] J. D. Hamilton, M. O′Donnell. High frequency ultrasound imaging with optical arrays [J]. IEEE Ultrasonics, Ferroelectrics, and Frequency Control, 1998, 45(1): 216~235

    [25] Lu Tao, Li Xiujuan, Mao Huiyong et al.. Photoacoustic tomography with Wiener filter deconvolution algorithm [J]. Acta Optica Sinica, 2009, 29(7): 1854~1857

    [26] Zhang Jian, Yang Sihua. Photoacoustic component imaging based on multi-spectral excitation [J]. Chinese J. Lasers, 2011, 38(1): 0104001

    [27] Xu Dong, Xiang Liangzhong, Ji Xuanrong. Photoacoustic imaging system based on inulti-channel parallel acquisition [J]. Chinese J. Lasers, 2011, 38(2): 0204002

    CLP Journals

    [1] Tan Bo, Hu Jianming, Yang Pan, Ding Shuaijun, Zhu Renjiang. Photoacoustic Tomography Imaging: An Emerging Detection Way[J]. Laser & Optoelectronics Progress, 2013, 50(4): 40005

    [2] Zhang Yu, Xue Yueju, Jia Jinliang, Jin Xiaoyong, Liu Hongshan, Xie Jiaxing. Real-Time Photoacoustic Imaging System Based on Phase Contrast Demodulation[J]. Laser & Optoelectronics Progress, 2016, 53(7): 71701

    [3] Yu Rong, Jiang Yuesong. Photoacoustic Spectroscopy System with Amplitude Spectrum and Phase Spectrum Measurement Functions[J]. Acta Optica Sinica, 2014, 34(2): 230001

    Zhang Yu, Tang Zhilie, Wu Yongbo, Xie Jiaxing, Dai Fen, Zhao Wenfeng. Study of Various Photoacoustic Imaging Methods[J]. Laser & Optoelectronics Progress, 2012, 49(2): 20004
    Download Citation