• Acta Optica Sinica
  • Vol. 19, Issue 10, 1386 (1999)
[in Chinese], [in Chinese], [in Chinese], [in Chinese], and [in Chinese]
Author Affiliations
  • [in Chinese]
  • show less
    DOI: Cite this Article Set citation alerts
    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Experimental Research of Optical Coherence Tomography[J]. Acta Optica Sinica, 1999, 19(10): 1386 Copy Citation Text show less
    References

    [1] Huang D, Swanson E A, Lin C P et al.. Optical coherence tomography. Science, 1991, 254(5035):1178~1181

    [2] Tearney G J, Brezinski M E, Bouma B E et al.. In vivo endoscopic optical biopsy with optical coherence tomography. Science, 1997, 276(5321):2037~2039

    [3] Tearney G J, Boppart S A, Bouma B E et al.. Scanning single-mode fiber optic catheter-endoscope for optical coherence tomography. Opt. Lett., 1996, 21(7):543~545

    [4] Wang Xiaojun, Milner T E et al.. Measurement of fluid-flow-velocity profile in turbid media by the use of optical Doppler tomography. Appl. Opt., 1997, 36(1):144~149

    [5] Devaraj B, Kobayashi M, Usa M et al.. First demonstration of laser computed tomography of human tooth by coherent detection imaging. Electron. Lett., 1995, 31(11):874~876

    [6] Chan K P, Yamada M, Devarajet B et al.. Optical imaging through highly scattering media by use of heterodyne detection in the 1.3 μm wavelength region. Opt. Lett., 1995, 20(5):492~494

    [7] Bashkansky M, Duncan M D, Kahn M et al.. Subsurface defect detection in ceramics by high-speed high-resolution optical coherent tomography. Opt. Lett., 1997, 22(1):61~63

    [8] Hee M R, Huang D, Swanson E A et al.. Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging. J. Opt. Soc. of Am. (B), 1992, 9(6):903~908

    [9] de Boer J F, Milner T E, van Gemert M J et al.. Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography. Opt. Lett., 1997, 22(12):934~936

    [10] Pan Yingtian, Birngruber R, Rosperich J et al.. Low-coherence optical tomography in turbid tissue: Theoretical analysis. Appl. Opt., 1995, 34(28):6564~6574

    [11] Schmitt J M, Knuttel A, Yadlowsky M et al.. Optical-coherence tomography of a dense tissue: Statistics of attenuation and backscattering. Phys. Med. Biol., 1994, 39(10):1705~1720

    [12] Schmitt J M, Knuttel A, Bonner R F. Measurement of optical properties of biological tissues by low-coherence reflectometry. Appl. Opt., 1993, 32(30):6032~6042

    [13] Massoud Motamedi, Sohi Rastegar. Light and temperature distribution in laser irradiated. Appl. Opt., 1989, 28(10):2230~2235

    [14] Pan Yingtian, Birngruber R, Engelhardt R. Contrast limits of coherence-gated imaging in scattering media. Appl. Opt., 1997, 36(13):2979~2983

    CLP Journals

    [1] Hu Zhixiong, Hao Bingtao, Liu Wenli, Hong Baoyu. Research on Point Spread Function Phantom Fabrication and Application for Evaluating Resolution Performance of OCT Systems[J]. Acta Optica Sinica, 2015, 35(4): 417001

    [2] Shi Guohua, Ding Zhihua, Dai Yun, Rao Xuejun, Zhang Yudong. Ophthalmic Imaging by Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2008, 35(9): 1429

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Experimental Research of Optical Coherence Tomography[J]. Acta Optica Sinica, 1999, 19(10): 1386
    Download Citation