• Opto-Electronic Engineering
  • Vol. 43, Issue 8, 59 (2016)
WEI Jiaotong*, CHEN Ping, and HAN Yan
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3969/j.issn.1003-501x.2016.08.010 Cite this Article
    WEI Jiaotong, CHEN Ping, HAN Yan. Applying Decomposition of Multi-voltage X-ray Images to Accomplish High Contrast Computed Tomography Imaging[J]. Opto-Electronic Engineering, 2016, 43(8): 59 Copy Citation Text show less
    References

    [1] JOSHUA D E,BRUCE R W,DAVID G P,et al. Experimental implementation of a polyenergetic statistical reconstruction algorithm for a commercial fan-beam CT scanner [J]. Physica Medica(S1120-1797),2013,29(5):500-512.

    [2] TSUCHIY A,UESUGI K,NAKANO T,et al. Quantitative evaluation of attenuation contrast of X-ray computed tomography images using monochromatized beams [J]. American Mineralogist(S0003-004X),2005,90(1):132-142.

    [3] MASETTI S,FIASCHETTI M,TURCO A,et al. Development of a Multi-Energy CT for Small Animals:Characterization of the Quasi-Monochromatic X-Ray Source [J]. IEEE Transactions on Nuclear Science(S0018-9499),2009,56(1):29-35.

    [4] SEMERCI O,HAO N,KILMER M E,et al. Tensor-based formulation and nuclear norm regularization for multi-energy computed tomography [J]. IEEE Transactions on Image Processing(S1057-7149),2014,23(4):1678-1693.

    [6] Cynthia H McCollough,LENG Shuai,YU Lifeng,et al. Dual-and Multi-Energy CT:Principles,Technical Approaches,and Clinical Applications [J]. Radiology(S0033-8419),2015,276(3):637–653.

    [7] RAKVONGTHAI Y,WORSTELL W,FAKHRI G,et al. Spectral CT Using Multiple Balanced K-Edge Filters [J]. IEEE Transactions on Medical Imaging(S0278-0062),2015,34(3):740-747.

    [10] GAO Hao,YU Hengyong,Osher Stanley,et al. Multi-energy CT based on a prior rank,intensity and sparsity model (PRISM) [J]. Inverse Problems(S0266-5611),2011,27(11):115012-115033.

    [11] KEZIOU A,FENNIRI H,GHAZDALI A,et al. New blind source separation method of independent/ dependent sources [J]. Signal Processing(S0165-1684),2014,104(6):319-324.

    [12] GILLIS N,GLINEUR F. Using underapproximations for sparse nonnegative matrix factorization [J]. Pattern Recognition (S0031-3203),2009,43(4):1676-1687.

    [13] XU Wei,LIU Xin,GONG Yihong. Document clustering based on non-negative matrix factorization [C]// Proceedings of the 26th annual international ACM SIGIR conference on Research and development in information retrieval,New York,July 28–August 1,2003:267-273.

    CLP Journals

    [1] MA Wei-hong, TIAN Hui, DONG Tao, NI Jin-ping. Checkout of External Trigger Delay in Linear Image Acquisition System[J]. Acta Photonica Sinica, 2018, 47(9): 911002

    WEI Jiaotong, CHEN Ping, HAN Yan. Applying Decomposition of Multi-voltage X-ray Images to Accomplish High Contrast Computed Tomography Imaging[J]. Opto-Electronic Engineering, 2016, 43(8): 59
    Download Citation