• Chinese Journal of Lasers
  • Vol. 48, Issue 9, 0904001 (2021)
Jiarui Lin, Jizhu Yu, Linghui Yang*, Rao Zhang, and Jigui Zhu
Author Affiliations
  • State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
  • show less
    DOI: 10.3788/CJL202148.0904001 Cite this Article Set citation alerts
    Jiarui Lin, Jizhu Yu, Linghui Yang, Rao Zhang, Jigui Zhu. Orientation Method of Distributed Measurement System Based on Hierarchical Geometric Constraints[J]. Chinese Journal of Lasers, 2021, 48(9): 0904001 Copy Citation Text show less
    Orientation schematic of distributed measurement system
    Fig. 1. Orientation schematic of distributed measurement system
    Schematic of wMPS measurement. (a) Single station angle measurement principle; (b) multi-station intersection measurement principle
    Fig. 2. Schematic of wMPS measurement. (a) Single station angle measurement principle; (b) multi-station intersection measurement principle
    Measurement model of biaxial inclination sensor
    Fig. 3. Measurement model of biaxial inclination sensor
    Datum length orientation model based on dip angle sensing
    Fig. 4. Datum length orientation model based on dip angle sensing
    Initial value solution method
    Fig. 5. Initial value solution method
    Simulation results of point position error. (a) z=-0.5 m; (b) z=0 m; (c) z=0.5 m; (d) z=1.0 m
    Fig. 6. Simulation results of point position error. (a) z=-0.5 m; (b) z=0 m; (c) z=0.5 m; (d) z=1.0 m
    Simulation result of length error
    Fig. 7. Simulation result of length error
    Experimental scene
    Fig. 8. Experimental scene
    Length error results
    Fig. 9. Length error results
    Orientation stability test. (a) Connecting line of reference ruler is parallel to baseline; (b) connecting line of reference ruler is perpendicular to baseline; (c) connecting line of reference ruler should be at certain angle to baseline 1; (d) connecting line of reference ruler should be at a certain angle to baseline 2
    Fig. 10. Orientation stability test. (a) Connecting line of reference ruler is parallel to baseline; (b) connecting line of reference ruler is perpendicular to baseline; (c) connecting line of reference ruler should be at certain angle to baseline 1; (d) connecting line of reference ruler should be at a certain angle to baseline 2
    Experimental results of orientation stability
    Fig. 11. Experimental results of orientation stability
    Number oftransmittersIndex oflaser planeabcd
    110-0.7620560.6475110
    2-0.7278380.0002930.6857480.223464
    210-0.7862190.6179470
    2-0.4772740.0051960.8787392.063871
    Table 1. Parameters of light plane of transmitting station
    Jiarui Lin, Jizhu Yu, Linghui Yang, Rao Zhang, Jigui Zhu. Orientation Method of Distributed Measurement System Based on Hierarchical Geometric Constraints[J]. Chinese Journal of Lasers, 2021, 48(9): 0904001