• Acta Optica Sinica
  • Vol. 39, Issue 11, 1112002 (2019)
Shuangshuang Zhu1、2、3、**, Hongchun Yang2、3、*, Zhenyang Li2、3, Xuefeng Lei1、2、3, Peng Zou2、3, Zhenhai Liu2、3, and Jin Hong2、3、***
Author Affiliations
  • 1School of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei, Anhui, 230026, China
  • 2Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, Anhui, 230031, China
  • 3Key Laboratory of Optical Calibration and Characterization of Chinese Academy of Sciences, Hefei, Anhui, 230031, China
  • show less
    DOI: 10.3788/AOS201939.1112002 Cite this Article Set citation alerts
    Shuangshuang Zhu, Hongchun Yang, Zhenyang Li, Xuefeng Lei, Peng Zou, Zhenhai Liu, Jin Hong. Polarization Detection Test and Result Analysis of Scanning Polarimeter[J]. Acta Optica Sinica, 2019, 39(11): 1112002 Copy Citation Text show less
    Optical measurement schematic of POSP
    Fig. 1. Optical measurement schematic of POSP
    Spectral extinction ratio of polarizer
    Fig. 2. Spectral extinction ratio of polarizer
    Diagram of on-ground test site of POSP
    Fig. 3. Diagram of on-ground test site of POSP
    Data processing results of on-ground test of POSP. (a) Radiation luminance; (b) degree of polarization
    Fig. 4. Data processing results of on-ground test of POSP. (a) Radiation luminance; (b) degree of polarization
    Data processing results of on-ground test of three-beam simultaneous polarization camera. (a) Degree of polarization of the sky; (b) radiation luminance of the sky
    Fig. 5. Data processing results of on-ground test of three-beam simultaneous polarization camera. (a) Degree of polarization of the sky; (b) radiation luminance of the sky
    Data processing results of in-flight test of POSP. (a) Radiation luminance; (b) degree of polarization
    Fig. 6. Data processing results of in-flight test of POSP. (a) Radiation luminance; (b) degree of polarization
    Data processing results of in-flight test of three-beam simultaneous polarization camera. (a) Degree of polarization of the earth's surface; (b) radiation luminance of the earth's surface
    Fig. 7. Data processing results of in-flight test of three-beam simultaneous polarization camera. (a) Degree of polarization of the earth's surface; (b) radiation luminance of the earth's surface
    ParameterMean of radiation luminance /(W·m-2·sr-1·μm-1)Mean of polarization degreeL| /%P|
    670 nm865 nm670 nm865 nm670 nm865 nm670 nm
    On-ground test of POSP9.6614.7320.2060.2412.7532.2430.011
    On-ground test of three-beam simultaneous polarization camera9.4024.8400.196-
    In-flight test of POSP14.9347.1960.3280.0964.5624.2060.017
    In-flight test of three-beam simultaneous polarization camera14.2837.5110.345-
    Table 1. Data comparison of polarization detection test of POSP and three-beam simultaneous polarization camera
    Shuangshuang Zhu, Hongchun Yang, Zhenyang Li, Xuefeng Lei, Peng Zou, Zhenhai Liu, Jin Hong. Polarization Detection Test and Result Analysis of Scanning Polarimeter[J]. Acta Optica Sinica, 2019, 39(11): 1112002
    Download Citation