[1] L. Xu, X. Peng, A. Asundi et al.. Hybrid holographic microscope for interferometric measurement of microstructures[J]. Opt. Engng., 2001, 40(11): 2533~2539
[2] L. Miccio, A. Finizio, S. Grilli et al.. Tunable liquid microlens arrays in electrode-less configuration and their accurate characterization by interference microscopy[J]. Opt. Express, 2009, 17(4): 2487~2499
[3] K. J. Stout, L. Blunt. Nanometres to micrometres: three-dimensional surface measurement in bio-engineering[J]. Surface and Coatings Technology, 1995, 71(2): 69~81
[4] C. Aktouf, B. Pannetier, P. Lemaitre-Auger et al.. On-line testing of embedded systems using optical probes: system modeling and probing technology[C]. Proceeding of the Eighth IEEE International On-Line Testing Workshop, 2002: 191
[5] S. Yoshida, S. Tanaka, M. Hirata et al.. Optical biopsy of GI lesions by reflectance-type laser-scanning confocal microscopy[J]. Gastrointestinal Endoscopy, 2007, 66(1): 144~149
[6] L. Jason, A. Robert. Detailed studies of molecular conductance using atomic resolution scanning tunneling microscopy[J]. Nano Lett., 2006, 6(3): 390~397
[7] Y. Niimi, T. Matsui, H. Kambara et al.. Scanning tunneling microscopy and spectroscopy of the electronic local density of states of graphite surfaces near monoatomic step edges[J]. Phys. Rev., 2006, 73(8): 085421-1~8
[8] Gui Min, Kuang Dengfeng, Fang Zhiliang. Measurement of surface topography of transmission phase grating based on phase measure method[J]. J. Optoelectronics·Laser, 2009, 20(10): 1337~1341
[10] Liu Jianping, Liang Liping, Jin Shilong et al.. Testing large curvature surface of optical element with spatial carrier heterodyne interferometry[J]. Infrared and Laser Engineering, 2009, 38(1): 110~113
[11] T. Colomb, E. Cuche, F. Charrière et al.. Automatic procedure for aberration compensation in digital holographic microscopy and applications to specimen shape compensation[J]. Appl. Opt., 2006, 45(5): 851~863
[13] J. Khn, T. Colomb, F. Montfort et al.. Real-time dual-wavelength digital holographic microscopy for MEMS characterization [C]. SPIE, 2007, 6716: 671608-1~10
[14] Y. Hao, A. Asundi. Comparison of digital holographic microscope and confocal microscope methods for characterization of micro-optical diffractive components[C]. SPIE, 2008, 7155: 71550B-1~10
[15] B. Kemper, S. Sturwald, C. Remmersmanna et al.. Characterisation of light emitting diodes (LEDs) for application in digital holographic microscopy for inspection of micro and nanostructured surfaces[J]. Opt. & Lasers in Enging., 2008, 46(7): 499~507
[16] Yuan Caojin, Zhai Hongchen, Wang Xiaolei et al.. Lensless digital holography with short-coherence light source for three-dimensional surface contouring of reflecting micro-object[J]. Opt. Commun., 2007, 270(2): 176~179
[17] M. M. Hossain, C. Shakher. Temperature measurement in laminar free convective flow using digital olography[J]. Appl. Opt., 2009, 48(10): 1869~1877
[18] P. Ferraro, S. D. Nicola, A. Finizio et al.. Compensation of the inherent wave front curvature in digital holographic coherent microscopy for quantitative phase-contrast imaging[J]. Appl. Opt., 2003, 42(11): 1938~1946
[20] Fan Qi, Zhano Jianlin, Xiang Qiang et al.. Methods of improving resolution of digital holographic microscopy[J]. J. Optoelectronics·Laser, 2005, 16(2): 226~230