• Acta Optica Sinica
  • Vol. 37, Issue 5, 511003 (2017)
Wang Jielin1、*, Liao Riwei1, Zeng Yaguang2, Xiao Hua1, and Tang Zhilie1、3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3788/aos201737.0511003 Cite this Article Set citation alerts
    Wang Jielin, Liao Riwei, Zeng Yaguang, Xiao Hua, Tang Zhilie. Three-Dimensional Imaging of Optical Projection Tomography Based on Normalized Dynamic Range-Transform[J]. Acta Optica Sinica, 2017, 37(5): 511003 Copy Citation Text show less
    References

    [1] Sharpe J, Ahlgren U, Perry P, et al. Optical projection tomography as a tool for 3D microscopy and gene expression studies[J]. Science, 2002, 296(5567): 541-545.

    [2] Schafer D, Gibson E A, Amir W, et al. Three-dimensional chemical concentration maps in a microfluidic device using two-photon absorption fluorescence imaging[J]. Optics letters, 2007, 32(17): 2568-2570.

    [3] Mc Ginty J, Taylor H B, Chen L, et al. In vivo fluorescence lifetime optical projection tomography[J]. Biomedical Optics Express, 2011, 2(5):1340-1350.

    [4] Wang Mao, Li Chunyan, Sun Yunfei, et al. Research of near-infrared small living animal fluorescence imaging system[J]. Acta Optica Sinica, 2013, 33(6): 0617003.

    [5] Bassi A, Fieramonti L, D′Andrea C, et al. In vivo label-free three-dimensional imaging of zebrafish vasculature with optical projection tomography[J]. Journal of Biomedical Optics, 2011, 16(10): 100502.

    [6] Ye Linlin, Xue Yanling, Tan Hai, et al. X-ray phase contrast micro-tomography and its application in quantitative 3D imaging study of wild ginseng characteristic microstructures[J]. Acta Optica Sinica, 2013, 33(12): 1234002.

    [7] Serov A, Lasser T. High-speed laser Doppler perfusion imaging using an integrating CMOS image sensor[J]. Optics Express, 2005, 13(17): 6416-6428.

    [8] Serov A, Steinacher B, Lasser T. Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera[J]. Optics Express, 2005, 13(10): 3681-3689.

    [9] Zhuang Tiange. CT principles and algorithms[M]. Shanghai: Shanghai Jiao Tong University Press, 1992.

    [10] Kak A C, Slaney M. Principles of computerized tomographic imaging[M]. New York: IEEE Press, 2001.

    [11] Wang Y, Wang R K. High-resolution computed tomography of refractive index distribution by transillumination low-coherence interferometry[J]. Optics Letters, 2010, 35(1): 91-93.

    [12] Chen L, McGinty J, Taylor H B, et al. Incorporation of an experimentally determined MTF for spatial frequency filtering and deconvolution during optical projection tomography reconstruction[J]. Optics Express, 2012, 20(7): 7323-7337.

    [13] Jacobs K, Loscos C, Ward G. Automatic high-dynamic range image generation for dynamic scenes[J]. IEEE Computer Graphics and Applications, 2008, 28(2): 84-93.

    [14] Fei P, Yu Z, Wang X, et al. High dynamic range optical projection tomography (HDR-OPT)[J]. Optics Express, 2012, 20(8): 8824-8836.

    [15] Zhu Xiuming. Research on construction and visualization of high dynamic range image[D]. Hangzhou: Zhejiang University, 2008.

    Wang Jielin, Liao Riwei, Zeng Yaguang, Xiao Hua, Tang Zhilie. Three-Dimensional Imaging of Optical Projection Tomography Based on Normalized Dynamic Range-Transform[J]. Acta Optica Sinica, 2017, 37(5): 511003
    Download Citation