• Acta Optica Sinica
  • Vol. 31, Issue 3, 311002 (2011)
Li Baolei1、2、* and Zhang Yaojun1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201131.0311002 Cite this Article Set citation alerts
    Li Baolei, Zhang Yaojun. Projection Decomposition Algorithm of X-Ray Dual-Energy Computed Tomography Based on Projection Matching[J]. Acta Optica Sinica, 2011, 31(3): 311002 Copy Citation Text show less
    References

    [1] Li Baolei, Yang Min, Fu Jian et al.. Two ring artifact correction methods for computed tomography[J]. Acta Optica Sinica, 2009, 29(7): 1849~1853

    [2] Fang Zheng, Sun Xiaomin, Luo Qingming. New simple method of X-ray beam hardening correction for CT reconstruction[J]. Acta Optica Sinica, 2007, 27(2): 302~306

    [3] Chen Xin, Sun Yi, Zhu Peiping. Reconstruction algorithm of cone|beam phase X-ray computer-tomography based on grating imaging[J]. Acta Optica Sinica, 2008, 28(6): 1079~1084

    [4] R. F. Eilbert, K. D. Krug. Aspects of image recognition in vivid technology′s dual-energy X-ray system for explosive detection[C].SPIE, 1992, 1824: 127~143

    [5] R. Alvarez, A. Macovski. Energy-selective reconstructions in X-ray computerized tomography [J]. Phys. Med. Biol., 1976, 21(5): 733~744

    [6] http://www.revealimaging.com/,2009.10.8

    [7] http://www.analogic.com/,2009.10.8

    [8] J. A. Fessler, I. Elbakri, P. Sukovic et al.. Maximum-likelihood dual-energy tomographic image reconstruction[C]. SPIE, 2002, 4684: 38~49

    [9] P. Sukovic, N. H. Clinthorne. Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography[J]. IEEE Trans. Med. Imag., 2000, 19(11): 1075~1081

    [10] G. Christ. Exact treatment of the dual-energy method in CT using polyenergetic X-ray spectra [J]. Phys. Med. Biol., 1984, 29(12): 1501~1510

    [11] J. C. M. Steenbeek, C. van Kuijk, J. L. Grashuis. Selection of fat-equivalent materials in postprocessing dual-energy quantitative CT[J]. Med. Phys., 1992, 19(4): 1051~1056

    [12] M. M. Goodsitt. Beam hardening errors in post-processing dual energy quantitative computed tomography[J]. Med. Phys., 1995, 22(7): 1039~1047

    [13] J. Peter Stonestrom, R. Alvarez, A. Macovski. A framework for spectral artifact corrections in X-ray CT[J]. IEEE Transactions on Biomedical Engineering, 1981, 28(2): 128~141

    [14] K. S. Chuang, H. K. Huang. A fast dual-energy computational method using iso-transmission lines and table lookup[J]. Med. Phys., 1987, 14(2): 186~192

    [15] R. E. Alvarez, J. A. Seibert, S. K. Thompson. Comparison of dual energy detector system performance[J]. Med. Phys., 2004, 31(3): 556~565

    [16] H. N. Cardinal, A. Fenster. An accurate method for direct dual-energy calibration and decomposition [J]. Med. Phys., 1990, 17(3): 327~341

    [17] W. A. Kalender, W. H. Perman, J. R. Vetter et al.. Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies[J]. Med. Phys., 1986, 13(3): 334~339

    [18] K.S. Chuang, H. K. Huang. Comparison of four dual energy image decomposition methods[J]. Phys. Med. Biol., 1988, 33(4): 455~466

    [19] Z. R. Ying, R. Naidu, K. Guilbert et al.. Dual energy volumetric X-ray tomographic sensor for luggage screening[C]. Proceedings of IEEE Sensors Applications Symposium, 2007, (6-8): 1~6

    [20] Z. R. Ying, R. Naidu , C. R. Crawford. Dual energy computed tomography for explosive detection[J]. J. X-ray Science and Technology, 2006, 14(4): 235~256

    [21] Guowei Zhang, Jianping Cheng, Li Zhang et al.. A practical reconstruction method for dual energy computed tomography[J]. J. X-Ray Science and Technology, 2008, 16(2): 67~88

    [22] http://sourceforge.net/projects/spectrumgui/,2009.12.18

    [23] http://physics.nist.gov/PhysRefData/XrayMassCoef/Cover.html,2009.12.18

    CLP Journals

    [1] Niu Suyun, Pan Jinxiao, Chen Ping. Multi-Spectrum Computed Tomography Imaging Method Based on Energy Spectrum Filtering Separation[J]. Acta Optica Sinica, 2014, 34(10): 1034001

    [2] Li Lei, Wang Linyuan, Cai Ailong, Han Yu, Yan Bin, Bao Shanglian. Projection Decomposition Algorithm for X-Ray Dual-Energy Computed Tomography Based on Isotransmission Line Fitting[J]. Acta Optica Sinica, 2016, 36(8): 834001

    [3] Fu Liqin, Wang Hongying, Zhang Ziliang. Auto Defect Extraction of Steel-Cord Conveyor Belt[J]. Chinese Journal of Lasers, 2012, 39(s1): 109001

    [4] Li Xingdong, Yang Min, Li Dehong, Liu Wenli. Improved Measurement Method for X-Ray Focus Projection Coordinates of 3D-CT Scanning System[J]. Acta Optica Sinica, 2011, 31(12): 1212004

    [5] Mo Jingqing, Xu Pin, Sun Mingshan. Projective Decomposition Algorithms for X-Ray Dual-Energy Bone Densitometer Based on Photon Counting Detectors[J]. Laser & Optoelectronics Progress, 2017, 54(10): 101102

    [6] Wang Junduo, Wang Riwei, Wen Xianbin, Zou Yongliao, Zheng Yongchun, Wang Ling. Fast Matching Algorithm of Lunar CCD Image[J]. Laser & Optoelectronics Progress, 2012, 49(1): 11102

    Li Baolei, Zhang Yaojun. Projection Decomposition Algorithm of X-Ray Dual-Energy Computed Tomography Based on Projection Matching[J]. Acta Optica Sinica, 2011, 31(3): 311002
    Download Citation