• Acta Optica Sinica
  • Vol. 38, Issue 1, 0115001 (2018)
Fan Yang1、2, Cheng Han1、2、*, Baoxing Bai1、2, and Chao Zhang1、2
Author Affiliations
  • 1 School of Computer Science and Technology, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • 2 National and Local Combined Engineering Research Center of Special Film Technology and Equipment, Changchun, Jilin 130022, China
  • show less
    DOI: 10.3788/AOS201838.0115001 Cite this Article Set citation alerts
    Fan Yang, Cheng Han, Baoxing Bai, Chao Zhang. Research on Parameter Calibration of Projection Correction System[J]. Acta Optica Sinica, 2018, 38(1): 0115001 Copy Citation Text show less
    Depth imaging model of intelligent perception system
    Fig. 1. Depth imaging model of intelligent perception system
    Generation of color pattern feature image
    Fig. 2. Generation of color pattern feature image
    Color information guided discrete hierarchical
    Fig. 3. Color information guided discrete hierarchical
    Coupling signal for single-channel of system
    Fig. 4. Coupling signal for single-channel of system
    Coupling signal for multi-channel of system
    Fig. 5. Coupling signal for multi-channel of system
    System coupling correction
    Fig. 6. System coupling correction
    Detection and recognition of corners
    Fig. 7. Detection and recognition of corners
    Detection performance of different algorithms on corner with noise
    Fig. 8. Detection performance of different algorithms on corner with noise
    Re-projection error of corner. (a) Camera; (b) projector
    Fig. 9. Re-projection error of corner. (a) Camera; (b) projector
    Distortion correction of projector
    Fig. 10. Distortion correction of projector
    EquipmentMethodfufvuvk1k2k3k4
    CameraRef. [10]3472.163568.37996.04758.430.08934-1.26736-0.15732-0.06427
    ProjectorRef. [10]1973.591978.62547.38824.19-0.034850.12681-0.016320.043981
    CameraRef. [11]3353.293601.04987.16684.190.09817-1.01462-0.20528-0.13056
    ProjectorRef. [11]1984.281990.72494.17842.68-0.026210.26433-0.060420.03475
    CameraProposed3465.523470.161023.43764.520.02532-0.86433-0.06042-0.00197
    ProjectorProposed1968.171969.45534.25806.74-0.011720.09768-0.008650.024382
    Table 1. Calibration results of intelligent projection system
    EquipmentMethodEmaxuEmaxvESTDuESTDvEmeanuEmeanv
    CameraRef. [10]0.5340.7610.4710.4930.3840.393
    ProjectorRef. [10]1.0231.2020.6430.5820.4280.476
    CameraRef. [11]0.7820.9360.5280.6320.4530.502
    ProjectorRef. [11]1.4371.3910.7920.7630.5390.527
    CameraProposed0.3380.3260.2740.2650.1920.203
    ProjectorProposed0.4370.5080.2430.1960.2030.245
    Table 2. Calibration error of intelligent projection system
    IndicatorProposed methodRef. [10] methodRef. [11] method
    Pmax2.632583.192243.41741
    Pmin-2.41683-3.02617-3.37593
    Pmean5.049416.218416.79334
    Vmax /(°)90.1924190.3162790.52715
    Vmin /(°)89.9177389.8181689.72953
    Vmean /(°)0.274680.498110.79762
    Table 3. Error analysis of plane parallelism and line perpendicularity
    Fan Yang, Cheng Han, Baoxing Bai, Chao Zhang. Research on Parameter Calibration of Projection Correction System[J]. Acta Optica Sinica, 2018, 38(1): 0115001
    Download Citation