• Laser & Optoelectronics Progress
  • Vol. 59, Issue 13, 1328002 (2022)
Xinkui Xing1、2、3, Xue Jiang1、2、3, Fanfan Liu1、2、3, Kabin Kuang1、2、3, and Heying Qin1、2、3、*
Author Affiliations
  • 1School of Civil and Architectural Engineering, Guilin University of Technology, Guilin 541004, Guangxi , China
  • 2Collaborative Innovation Center for Exploration of Nonferrous Metal Deposits and Efficient Utilization of Resources, Guilin University of Technology, Guilin 541004, Guangxi , China
  • 3Guangxi Key Laboratory of Geomechanics and Geotechnical Engineering, Guilin 541004, Guangxi , China
  • show less
    DOI: 10.3788/LOP202259.1328002 Cite this Article Set citation alerts
    Xinkui Xing, Xue Jiang, Fanfan Liu, Kabin Kuang, Heying Qin. Fiber Bragg Grating Humidity Sensor Based on Polyimide Material[J]. Laser & Optoelectronics Progress, 2022, 59(13): 1328002 Copy Citation Text show less
    Schematic diagram of the FBG humidity sensor
    Fig. 1. Schematic diagram of the FBG humidity sensor
    Experimental product of PI coating film
    Fig. 2. Experimental product of PI coating film
    Experimental system of the FBG humidity sensor
    Fig. 3. Experimental system of the FBG humidity sensor
    Humidity sensing characteristic curves of FBG coated with PI films of different thickness. (a) 0.13 mm; (b) 0.23 mm; (c) 0.35 mm
    Fig. 4. Humidity sensing characteristic curves of FBG coated with PI films of different thickness. (a) 0.13 mm; (b) 0.23 mm; (c) 0.35 mm
    Sample and the bubbles it presents
    Fig. 5. Sample and the bubbles it presents
    Simulation results under constant humidity. (a) Temperature sensing characteristic curve; (b) temperature sensitivity curve
    Fig. 6. Simulation results under constant humidity. (a) Temperature sensing characteristic curve; (b) temperature sensitivity curve
    Humidity sensing characteristic curve under constant temperature (thickness: 0.13 mm)
    Fig. 7. Humidity sensing characteristic curve under constant temperature (thickness: 0.13 mm)
    TypeOuter diameter /mmInner diameter /mmThickness /mm
    Sample0.180.150.07
    0.240.200.13
    0.340.300.23
    0.460.400.35
    0.560.500.45
    Table 1. Parameters of experimental samples
    Thickness /mmLength /mmSensitivity /(pm%RH)Fitting
    0.13105.50.99
    205.40.99
    305.40.99
    0.23105.60.95
    205.70.95
    305.70.95
    0.35101.70.99
    207.20.92
    306.50.92
    405.00.94
    504.40.94
    Table 2. Humidity sensing characteristics and fitting degree of FBG films coated with PI films of different thickness and length