• Journal of Innovative Optical Health Sciences
  • Vol. 13, Issue 6, 2050030 (2020)
Jessica Mavadia-Shukla, Jianlin Zhang, Kaiyan Li, and Xingde Li*
Author Affiliations
  • Department of Biomedical Engineering Johns Hopkins University Baltimore, MD 21205, USA
  • show less
    DOI: 10.1142/s1793545820500303 Cite this Article
    Jessica Mavadia-Shukla, Jianlin Zhang, Kaiyan Li, Xingde Li. Stick-slip nonuniform rotation distortion correction in distal scanning optical coherence tomography catheters[J]. Journal of Innovative Optical Health Sciences, 2020, 13(6): 2050030 Copy Citation Text show less
    References

    [1] M. J. Gora, M. J. Suter, G. J. Tearney, X. D. Li, "Endoscopic optical coherence tomography: Technologies and clinical applications [Invited]," Biomed. Opt. Express 8(5), 2405–2444 (2017).

    [2] P. R. Herz, Y. Chen, A. D. Aguirre, K. Schneider, P. Hsiung, J. G. Fujimoto, K. Madden, J. Schmitt, J. Goodnow, N. C. Petersen, "Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography," Opt. Lett. 29(19), 2261–2263 (2004).

    [3] P. H. Tran, D. S. Mukai, M. Brenner, Z. P. Chen, "In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe," Opt. Lett. 29(11), 1236–1238 (2004).

    [4] J. Mavadia, J. F. Xi, Y. P. Chen, X. D. Li, "An all- fiber-optic endoscopy platform for simultaneous OCT and fluorescence imaging," Biomed. Opt. Express 3(11), 2851–2859 (2012).

    [5] M. J. Gora, J. S. Sauk, R. W. Carruth, K. A. Gallagher, M. J. Suter, N. S. Nishioka, L. E. Kava, M. Rosenberg, B. E. Bouma, G. J. Tearney, "Tethered capsule endomicroscopy enables less invasive imaging of gastrointestinal tract microstructure," Nat. Med. 19(2), 238–240 (2013).

    [6] T. S. Wang,W.Wieser, G. Springeling, R. Beurskens, C. T. Lancee, T. Pfei?er, A. F. W. van der Steen, R. Huber, G. van Soest, "Intravascular optical coherence tomography imaging at 3200 frames per second," Opt. Lett. 38(10), 1715–1717 (2013).

    [7] K. C. Liang, Z. Wang, O. O. Ahsen, H. C. Lee, B. M. Potsaid, V. Jayaraman, A. Cable, H. Mashimo, X. D. Li, J. G. Fujimoto, "Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo," Optica 5(1), 36–43 (2018).

    [8] J. Mavadia-Shukla, P. Fathi, W. Liang, S. Wu, C. Sears, X. Li, "High-speed, ultrahigh-resolution distal scanning OCT endoscopy at 800 nm for in vivo imaging of colon tumorigenesis on murine models," Biomed. Opt. Express 9(8), 3731–3739 (2018).

    [9] K. Y. Li, W. X. Liang, J. Mavadia-Shukla, H. C. Park, D. W. Li, W. Yuan, S. R. Wan, X. D. Li, "Super-achromatic optical coherence tomography capsule for ultrahigh-resolution imaging of esophagus," J. Biophotonics 12(3), e201800205 (2019).

    [10] B. Potsaid, B. Baumann, D. Huang, S. Barry, A. E. Cable, J. S. Schuman, J. S. Duker, J. G. Fujimoto, "Ultrahigh speed 1050 nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second," Opt. Express 18(19), 20029–20048 (2010).

    [11] V. Jayaraman, J. Jiang, H. Li, P. J. S. Heim, G. D. Cole, B. Potsaid, J. G. Fujimoto, A. Cable, "OCT imaging up to 760 kHz axial scan rate using singlemode 1310 nm MEMS-tunable VCSELs with > 100 nm tuning range," Conf. Laser Electr., (2011), p. PDPB2.

    [12] B. Potsaid, V. Jayaraman, J. G. Fujimoto, J. Jiang, P. J. S. Heim, A. E. Cable, "MEMS tunable VCSEL light source for ultrahigh speed 60 kHz-1MHz axial scan rate and long range centimeter class OCT imaging," Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine Xvi, Vol. 8213 (2012).

    [13] W. Wieser, B. R. Biedermann, T. Klein, C. M. Eigenwillig, R. Huber, "Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second," Opt. Express 18(14), 14685–14704 (2010).

    [14] J. A. Li, M. de Groot, F. Helderman, J. H. Mo, J. M. A. Daniels, K. Grunberg, T. G. Sutedja, J. F. de Boer, "High speed miniature motorized endoscopic probe for optical frequency domain imaging," Opt. Express 20(22), 24132–24138 (2012).

    [15] T. H. Tsai, B. Potsaid, Y. K. Tao, V. Jayaraman, J. Jiang, P. J. S. Heim, M. F. Kraus, C. Zhou, J. Hornegger, H. Mashimo, A. E. Cable, J. G. Fujimoto, "Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology," Biomed. Opt. Express 4(7), 1119–1132 (2013).

    [16] G. van Soest, J. G. Bosch, A. F. W. van der Steen, "Azimuthal registration of image sequences affected by nonuniform rotation distortion," IEEE Trans. Inf. Technol. Biomed. 12(3), 348–355 (2008).

    [17] H. ten Ho?, A. Korbijn, T. H. Smith, J. F.Klinkhamer, N. Bom, "Imaging artifacts in mechanically driven ultrasound catheters," Int. J. Card. Imaging 4(2–4), 195–199 (1989).

    [18] N. Uribe-Patarroyo, B. E. Bouma, "Rotational distortion correction in endoscopic optical coherence tomography based on speckle decorrelation," Opt. Lett. 40(23), 5518–5521 (2015).

    [19] W. Kang, H. Wang, Z. Wang, M. W. Jenkins, G. A. Isenberg, A. Chak, A. M. Rollins, "Motion artifacts associated with in vivo endoscopic OCT images of the esophagus," Opt. Express 19(21), 20722–20735 (2011).

    [20] G. J. Ughi, T. Adriaenssens, M. Larsson, C. Dubois, P. R. Sinnaeve, M. Coosemans, W. Desmet, J. D'hooge, "Automatic three-dimensional registration of intravascular optical coherence tomography images," J. Biomed. Optics 17(2), 026005 (2012).

    [21] O. O. Ahsen, H. C. Lee, M. G. Giacomelli, Z. Wang, K. C. Liang, T. H. Tsai, B. Potsaid, H. Mashimo, J. G. Fujimoto, "Correction of rotational distortion for catheter-based en face OCT and OCT angiography," Opt. Lett. 39(20), 5973–5976 (2014).

    [22] A.Ahmad, S.G.Adie, E. J. Chaney,U. Sharma, S. A. Boppart, "Cross-correlation-based image acquisition technique for manually-scanned optical coherence tomography," Opt. Express 17(10), 8125–8136 (2009).

    [23] A. Lopez-Marin, G. Springeling, R. Beurskens, H. M. M. van Beusekom, A. F. W. van der Steen, A. D. Koch, B. E. Bouma, R. A. Huber, G. van Soest, T. S. Wang, "Shadow-free motorized capsule enables accurate beam positioning and sectorized OCT imaging of the esophagus," Proc. SPIE Endoscopic Microscopy Xv Vol. 11214 (2020).

    Jessica Mavadia-Shukla, Jianlin Zhang, Kaiyan Li, Xingde Li. Stick-slip nonuniform rotation distortion correction in distal scanning optical coherence tomography catheters[J]. Journal of Innovative Optical Health Sciences, 2020, 13(6): 2050030