    Rui-rui ZHANG, Wei-qian ZHAO, Yun WANG, Li-rong QIU. High-Stability Confocal Raman Microscopy Imaging Method Based on Bilateral Fitting Subtracting Confocal Microscopy[J]. Spectroscopy and Spectral Analysis, 2021, 41(9): 2795 Copy Citation Text show less
    Diagram of confocal Raman microscopy
    Fig. 1. Diagram of confocal Raman microscopy
    The relationship between the lateral FWHM and the defocusing amount u
    Fig. 2. The relationship between the lateral FWHM and the defocusing amount u
    (a) Influence of axial scanning pitch on RMSE at different spherical aberration; (b) Influence of axial scanning pitch on RMSE at different astigmatism; (c) Influence of axial scanning pitch on RMSE at different SNR
    Fig. 3. (a) Influence of axial scanning pitch on RMSE at different spherical aberration; (b) Influence of axial scanning pitch on RMSE at different astigmatism; (c) Influence of axial scanning pitch on RMSE at different SNR
    Actual axial response curve and focusing result of BFSCRMCI is the actual curve; lL and lR are fitting lines; lD is difference line; zf=199.695 μm is the focus position
    Fig. 4. Actual axial response curve and focusing result of BFSCRM
    CI is the actual curve; lL and lR are fitting lines; lD is difference line; zf=199.695 μm is the focus position
    Focusing repetition accuracy of BFSCRM
    Fig. 5. Focusing repetition accuracy of BFSCRM
    (a) microscopic observation image; (b) zoom-in the area shown in red area of (a); (c) Raman spectrum of point A in (a)
    Fig. 6. (a) microscopic observation image; (b) zoom-in the area shown in red area of (a); (c) Raman spectrum of point A in (a)
    Raman images of a vertical bar with a 5 μm period(a): Without auto-focusing; (b): Using BFSCRM
    Fig. 7. Raman images of a vertical bar with a 5 μm period
    (a): Without auto-focusing; (b): Using BFSCRM