• Acta Optica Sinica
  • Vol. 31, Issue 1, 112004 (2011)
He Yingwei1、*, Li Ping2, Feng Guojin2, Wang Yu2, Liu Zilong2, Zheng Chundi2, Wu Houping2, Li Cheng2, and Sha Dingguo1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201131.0112004 Cite this Article Set citation alerts
    He Yingwei, Li Ping, Feng Guojin, Wang Yu, Liu Zilong, Zheng Chundi, Wu Houping, Li Cheng, Sha Dingguo. Analysis of a Sub-Aperture Scanning Machine with Double-Rotating Arms for Large-Aperture Optical System Transmittance Measurements[J]. Acta Optica Sinica, 2011, 31(1): 112004 Copy Citation Text show less
    References

    [1] Q. Dong, T. Jiang, S. Zhang et al.. Telescopic optical system transmittance detection based on the cross-correlation techinque[J]. Acta Armamentarii, 2006, 27(6): 1103~1105

    [2] H. Wang, G. Cao, H. Ding. Detecting research on transmission of optical system based on bright field[J]. Machinery Design & Manufacture, 2009, (12): 223~224

    [3] D. T. Su, D. Shang, J. Lin et al.. Optical Testing Technology[M]. Beijing: Beijing Institute of Technology Press, 1996. 43~47

    [4] L. An, L. Li, Q. Li. Applied Optics[M]. Beijing: Beijing Institute of Technology Press, 2000. 122~126

    [5] Y. Q. Li, Y. F. Zhang, G. R. Zhang. A new test method for short-focus-length optical system[J]. Acta Metrologica Sinica, 2009, 30(6A): 89~91

    [6] Y. Hao, C. Yang. A new testing method of transmittancy of camera with large aperture[J]. Spacecraft Recovery & Remote Sensing, 1996, 17(4): 22~29

    [7] Y. Xie, J. Liu, H. Li et al.. Measuring spectrual reflectance and transmittance of heavy caliber optical thin-film[J]. Optical Instruments, 2004, 26(2): 164~167

    [8] Y. Li, Y. Tang, Z. Lin et al.. Design of apochromatism objective lens of aerial camera based on large frame array CCD[J]. Acta Optica Sinica, 2009, 29(11): 3183~3185

    [9] R. R. Zhang, W. M. Shen. Long focal-length optical system using annular aperture[J]. Acta Optica Sinica, 2010, 30(4): 1140~1143

    [10] Z. Chao, X. B. Peng, X. Z. Xing. Observation planning of LAMOST fiber positioning sub-system and its simulation study[C]. SPIE, 2003, 4837(2): 556~563

    [11] X. B. Peng, H. Z. Hu, C. Zhai et al.. Study on the construction of LAMOST sub-system[J]. Chinese Journal of Scientific Instrument, 2003, 24(z1): 341~343

    [12] S. W. Lin, P. P. Wang, Y. T. Fei. Simulation of the errors transfer in an articulation-type coordinate measuring machine[J]. Int. J. Adv. Manuf. Technol, 2006, 30(9): 879~886

    [13] H. F. F. Castro. Uncertainty analysis of a laser calibration system for evaluating the positioning accuracy of a numerically controlled axis of coordinate measuring machines and machine tools[J]. Precision Engineering, 2008, 32(2): 106~113

    [14] K. Song, Z. Jiang. Estimation of measuring uncertainty for optical micro-coordinate measuring machine[J]. Chin. Opt. Lett., 2004, 2(12): 704~707

    [15] Z. Chao, X. Z. Xing, H. Z. Hu et al.. The design of control system for fiber positioning system of LAMOST[C]. SPIE, 2003, 4837(2): 494~501

    [16] T. T. Liao, P. D. Lin. Analysis of optical elements with flat boundary surfaces[J]. Appl. Opt., 2003, 42(7): 1191~1202

    [17] T. T. Liao. A skew ray tracing-based approach to the error analysis of optical elements with flat boundary surfaces[J]. Optik, 2008, 119(15): 713~722

    CLP Journals

    [1] Chen Yiwei, Wang Fei, Wang Gaowen, Sui Yongxin, Yang Huaijiang. New Sub-Aperture Stitching Algorithm Based on Transformation[J]. Acta Optica Sinica, 2013, 33(9): 912004

    [2] Liu Xinbo, Wang Zhong, Su Ye, Liu Hongguang, Zhu Jigui. Measurement of Parallelism Between Rotating Axis and Guideway of a Machine Tool Based on Approximation Hole Center Positioning Method[J]. Chinese Journal of Lasers, 2012, 39(11): 1108015

    [3] Pei Linlin, Huang Min, Lü Qunbo, Fu Qiang. Effect of Angle Error of the Double Amici Prism on Dispersion[J]. Acta Optica Sinica, 2013, 33(1): 122003

    He Yingwei, Li Ping, Feng Guojin, Wang Yu, Liu Zilong, Zheng Chundi, Wu Houping, Li Cheng, Sha Dingguo. Analysis of a Sub-Aperture Scanning Machine with Double-Rotating Arms for Large-Aperture Optical System Transmittance Measurements[J]. Acta Optica Sinica, 2011, 31(1): 112004
    Download Citation