• Spectroscopy and Spectral Analysis
  • Vol. 35, Issue 12, 3534 (2015)
LIN Jun*, SHAO Jun, SONG Chao-yu, LI Yun-wei, and LEI Yu-fei
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3964/j.issn.1000-0593(2015)12-3534-04 Cite this Article
    LIN Jun, SHAO Jun, SONG Chao-yu, LI Yun-wei, LEI Yu-fei. High Precision Spectral Calibration Method of Fourier Interferometric Spectrometer[J]. Spectroscopy and Spectral Analysis, 2015, 35(12): 3534 Copy Citation Text show less

    Abstract

    The Fourier interferometric spectrometer (FIS) acquires the interference data information of the spectrum and during the spectrum data processing, a series of spectrum reconstruction will be performed on the interference information to obtain the final spectrum information data. The spectral calibration is the key step to spectrum reconstruction of FIS, which directly determines accuracy and availability of the spectrum results. This paper introduces the basic ideas and calibration accuracy about the spectral calibration for the FIS and puts forward a new spectral calibration method based on calculating the precise value of the total optical path difference (TOPD). The TOPD of FIS is difficult to be precisely measured, but it is the core and key to the spectral calibration. In order to calculate the precise TOPD, this paper proposes the idea how to traverse the TOPD and analyzes the spectrum drift. During the calibration, all the possible values of the TOPD participate in the spectrum reconstruction flow to carry out spectrum recovery and analysis. Ultimately the TOPD with the minimum spectrum drift will be achieved, namely solution value of the TOPD. This method can accurately resolve the TOPD of the FIS and then calibrate the spectrum with high accuracy. In addition, the paper introduces the detailed and complete spectral calibration flow and obtains the center wavelength value of every band and wavenumber resolution. Moreover, the paper designs the main parameters of the typical FIS and generates its simulation interference data. Using the above method to calibrate the simulation data, the analysis and verification of the spectral calibration results proves that the calibration precision of wavenumber resolution achieves 0.000 25 cm-1 or above.
    LIN Jun, SHAO Jun, SONG Chao-yu, LI Yun-wei, LEI Yu-fei. High Precision Spectral Calibration Method of Fourier Interferometric Spectrometer[J]. Spectroscopy and Spectral Analysis, 2015, 35(12): 3534
    Download Citation