• High Power Laser and Particle Beams
  • Vol. 34, Issue 11, 115001 (2022)
An He1、2, Fan Guo1、2, Junjun Kang1、2, Minghe Xia1、2, Yu Ding1, Liangji Zhou1、2, Lidong Geng1、2, Bing Wei1、2, Jianqiang Yuan1、2, and Weiping Xie1、2
Author Affiliations
  • 1Institute of Fluid Physics, CAEP, Mianyang 621900, China
  • 2Key Laboratory of Pulsed Power, CAEP, Mianyang 621900, China
  • show less
    DOI: 10.11884/HPLPB202234.220170 Cite this Article
    An He, Fan Guo, Junjun Kang, Minghe Xia, Yu Ding, Liangji Zhou, Lidong Geng, Bing Wei, Jianqiang Yuan, Weiping Xie. Trigger system of the middle energy X-ray device[J]. High Power Laser and Particle Beams, 2022, 34(11): 115001 Copy Citation Text show less
    Schematic diagram of the middle energy X-ray machine
    Fig. 1. Schematic diagram of the middle energy X-ray machine
    Path of the laser trigger switch
    Fig. 2. Path of the laser trigger switch
    Installation graph of laser tube and laser-switch
    Fig. 3. Installation graph of laser tube and laser-switch
    Layout of the electricity-trigger unit
    Fig. 4. Layout of the electricity-trigger unit
    Picture of the trigger unit and No.0-laser
    Fig. 5. Picture of the trigger unit and No.0-laser
    Block diagram of triggering suquence for the middle energy X-ray device
    Fig. 6. Block diagram of triggering suquence for the middle energy X-ray device
    Laser pulse and voltage waveform of trigger output
    Fig. 7. Laser pulse and voltage waveform of trigger output
    Statistical delay time of the middle energy X-ray device for 50 consecutive shots
    Fig. 8. Statistical delay time of the middle energy X-ray device for 50 consecutive shots
    An He, Fan Guo, Junjun Kang, Minghe Xia, Yu Ding, Liangji Zhou, Lidong Geng, Bing Wei, Jianqiang Yuan, Weiping Xie. Trigger system of the middle energy X-ray device[J]. High Power Laser and Particle Beams, 2022, 34(11): 115001
    Download Citation