• Infrared and Laser Engineering
  • Vol. 54, Issue 5, 20250112 (2025)
Haisheng FENG1,2, Jian WEN1,2, Su WU1, Tao WANG1,2..., Shanshan ZHENG1,2, Zhanjun LING1,2, Hui XUE1 and Lei YU1|Show fewer author(s)
Author Affiliations
  • 1Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
  • 2Science Island Branch, Graduate School of USTC, Hefei 230026, China
  • show less
    DOI: 10.3788/IRLA20250112 Cite this Article
    Haisheng FENG, Jian WEN, Su WU, Tao WANG, Shanshan ZHENG, Zhanjun LING, Hui XUE, Lei YU. Optical system design of a hyper-spectral imaging sensor in broadband with large field of view for land observation(inner cover paper·invited)[J]. Infrared and Laser Engineering, 2025, 54(5): 20250112 Copy Citation Text show less
    Optical path of the telescope
    Fig. 1. Optical path of the telescope
    Design results of MTF in all fields of view of the broadband
    Fig. 2. Design results of MTF in all fields of view of the broadband
    Optical path of the advanced Dyson spectrometer
    Fig. 3. Optical path of the advanced Dyson spectrometer
    Design of the advanced Dyson spectral imaging system
    Fig. 4. Design of the advanced Dyson spectral imaging system
    Design results of the advanced Dyson spectral imaging system
    Fig. 5. Design results of the advanced Dyson spectral imaging system
    The optical paths of the imaging spectrometer
    Fig. 6. The optical paths of the imaging spectrometer
    Full-system spot diagrams
    Fig. 7. Full-system spot diagrams
    Design results of the total system
    Fig. 8. Design results of the total system
    Prototype of hyperspectral imager
    Fig. 9. Prototype of hyperspectral imager
    Test results of spectral resolution
    Fig. 10. Test results of spectral resolution
    Wavelength calibration experiment
    Fig. 11. Wavelength calibration experiment
    Field observation results
    Fig. 12. Field observation results
    Central wavelength/mmFWHM/mmCentral wavelength/mmFWHM/mm
    379.532.01680.052.07
    429.472.14729.632.05
    479.952.09779.652.03
    529.292.15830.372.19
    579.802.07880.242.07
    629.411.98899.572.07
    Table 1. Results of wavelength calibration