• Photonic Sensors
  • Vol. 9, Issue 2, 126 (2019)
Haifeng DU, Xiaoyan SUN, Youwang HU*, Xinran DONG, and Jianhang ZHOU
Author Affiliations
  • State Key Laboratory of High Performance Complex Manufacturing, College of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China
  • show less
    DOI: 10.1007/s13320-019-0532-2 Cite this Article
    Haifeng DU, Xiaoyan SUN, Youwang HU, Xinran DONG, Jianhang ZHOU. High Sensitive Refractive Index Sensor Based on Cladding Etched Photonic Crystal Fiber Mach-Zehnder Interferometer[J]. Photonic Sensors, 2019, 9(2): 126 Copy Citation Text show less
    References

    [1] X. Y. Sun, X. R. Dong, Y. W. Hu, H. T. Li, D. K. Chu, J. Y. Zhou, et al., “A robust high refractive index sensitivity fiber Mach-Zehnder interferometer fabricated by femtosecond laser machining and chemical etching,” Sensors & Actuators A: Physical, 2015, 230: 111.116.

    [2] J. H. Wo, G. H. Wang, Y. Cui, Q. Sun, R. B. Liang, P. Shum, et al., “Refractive index sensor using microfiber-based Mach-Zehnder interferometer,” Optics Letters, 2012, 37(1): 67.69.

    [3] Q. Wang, L. X. Kong, Y. L. Dang, F. Xia, Y. W. Zhang, Y. Zhao, et al., “High sensitivity refractive index sensor based on splicing points tapered SMF-PCF-SMF structure Mach-Zehnder mode interferometer,” Sensors & Actuators B: Chemical, 2016, 225: 213.220.

    [4] J. N. Wang and J. L. Tang, “Photonic crystal fiber Mach-Zehnder interferometer for refractive index sensing,” Sensors, 2012, 12(3): 2983.2995.

    [5] B. Y. Li, L. Jiang, S. M. Wang, H. L. Tsai, and H. Xiao, “Femtosecond laser fabrication of long period fiber gratings and applications in refractive index sensing,” Optics & Laser Technology, 2011, 43(8): 1420.1423.

    [6] F. Zou, Y. Q. Liu, C. L. Deng, Y. H. Dong, S. Zhu, and T. Y. Wang, “Refractive index sensitivity of nano-film coated long-period fiber gratings,” Optics Express, 2015, 23(2): 1114.1124.

    [7] W. Liang, Y. Huang, Y. Xu, R. K. Lee, and A. Yariv, “Highly sensitive fiber Bragg grating refractive index sensors,” Applied Physics Letters, 2005, 86(15): 151122-1.151122-3.

    [8] T. Wei, Y. K. Han, Y. J. Li, H. L. Tsai, and H. Xiao, “Temperature-insensitive miniaturized fiber inline Fabry-Perot interferometer for highly sensitive refractive index measurement,” Optics Express, 2008, 16(8): 5764.5769.

    [9] X. Y. Sun, D. K. Chu, X. R. Dong, C. Zhou, H. T. Li, L. Zhi, et al., “Highly sensitive refractive index fiber inline Mach-Zehnder interferometer fabricated by femtosecond laser micromachining and chemical etching,” Optics & Laser Technology, 2016, 77: 11.15.

    [10] P. Lu, L. Q. Men, K. Sooley, and Q. Chen, “Tapered fiber Mach-Zehnder interferometer for simultaneous measurement of refractive index and temperature,” Applied Physics Letters, 2009, 94(13): 131110-1.131110-3.

    [11] X. R. Dong, Z. Xie, Y. X. Song, K. Yin, D. K. Chu, and J. A. Duan, “High temperature-sensitivity sensor based on long period fiber grating inscribed with femtosecond laser transversal-scanning method,” Chinese Optics Letters, 2017, 15(9): 090602-1.090602-5.

    [12] X. R. Dong, Z. Xie, C. Zhou, K. Yin, Z. Luo, and J. A. Duan, “Temperature sensitivity enhancement of platinum-nanoparticle-coated long period fiber gratings fabricated by femtosecond laser,” Applied Optics, 2017, 56(23): 6549.6553.

    [13] T. A. Birks, J. C. Knight, and P. S. J. Russell, “Endlessly single-mode photonic crystal fiber,” Optics Letters, 1997, 22(13): 961.963.

    [14] Y. Zhao, X. G. Li, L. Cai, and Y. Yang, “Refractive index sensing based on photonic crystal fiber interferometer structure with up-tapered joints,” Sensors & Actuators B: Chemical, 2015, 221: 406.410.

    [15] D. Wu, Y. Zhao, and J. Li, “PCF taper-based Mach-Zehnder interferometer for refractive index sensing in a PDMS detection cell,” Sensors & Actuators B: Chemical, 2015, 213: 1.4.

    [16] Y. Zhao, F. Xia, H. F. Hu, and M. Q. Chen, “A novel photonic crystal fiber Mach-Zehnder interferometer for enhancing refractive index measurement sensitivity,” Optics Communications, 2017, 402: 368.374.

    [17] D. Pawar and S. N. Kale, “Birefringence manipulation in tapered polarization-maintaining photonic crystal fiber Mach-Zehnder interferometer for refractive index sensing,” Sensors & Actuators A: Physical, 2016, 252: 180.184.

    [18] Y. C. Tan, Z. Q. Tou, V. Mamidala, K. K. Chow, and C. C. Chan, “Continuous refractive index sensing based on carbon-nanotube-deposited photonic crystal fibers,” Sensors & Actuators B: Chemical, 2014, 202: 1097.1102.

    [19] L. Melo, G. Burton, P. Kubik, and P. Wild, “Refractive index sensor based on inline Mach-Zehnder interferometer coated with hafnium oxide by atomic layer deposition,” Sensors and Actuators B: Chemical, 2016, 236: 537.545.

    [20] T. Zhu, F. F. Xiao, L. C. Xu, M. Liu, M. Deng, and K. S. Chiang, “Pressure-assisted low-loss fusion splicing between photonic crystal fiber and single-mode fiber,” Optics Express, 2012, 20(22): 24465.24471.

    [21] D. K. Sharma and A. Sharma. “Mode field expansion in index-guiding microstructured optical fibers,” SPIE, 2013, 8794: 87942A-1.87942A-6.

    [22] L. C. Li, L. Xia, Z. H. Xie, and D. M. Liu, “All-fiber Mach-Zehnder interferometers for sensing applications,” Optics Express, 2012, 20(10): 11109.11120.

    [23] Y. Zhao, M. Q. Chen, F. Xia, and H. F. Hu, “Spectrum online-tunable Mach-Zehnder interferometer based on step-like tapers and its refractive index sensing characteristics,” Optics Communications, 2017, 403: 143.149.

    [24] L. Cai, Y. Zhao, and X. G. Li, “A fiber ring cavity laser sensor for refractive index and temperature measurement with core-offset modal interferometer as tunable filter,” Sensors & Actuators B: Chemical, 2017, 242: 673.678.

    [25] R. Xiong, H. Y. Meng, Q. Q. Yao, B. Huang, Y. M. Liu, H. C. Xue, et al., “Simultaneous measurement of refractive index and temperature based on modal interference,” IEEE Sensors Journal, 2014, 14(8): 2524–2528.

    [26] L. Q. Wang, L. Yang, C. Zhang, C. Y. Miao, J. F. Zhao, and W. Xu, “High sensitivity and low loss open-cavity Mach-Zehnder interferometer based on multimode interference coupling for refractive index measurement,” Optics and Laser Technology, 2019, 109: 193–198.

    CLP Journals

    [1] Xiaoyan SUN, Haifeng DU, Xinran DONG, Youwang HU, Ji’an DUAN. Simultaneous Curvature and Temperature Sensing Based on a Novel Mach-Zehnder Interferometer[J]. Photonic Sensors, 2020, 10(2): 171

    Haifeng DU, Xiaoyan SUN, Youwang HU, Xinran DONG, Jianhang ZHOU. High Sensitive Refractive Index Sensor Based on Cladding Etched Photonic Crystal Fiber Mach-Zehnder Interferometer[J]. Photonic Sensors, 2019, 9(2): 126
    Download Citation