• Spectroscopy and Spectral Analysis
  • Vol. 41, Issue 9, 2812 (2021)
Ya-bing WANG*, Shang-kun SHAO1; 2;, Xue-peng SUN1; 2;, Xiao-yun ZHANG1; 2;, Hui-quan LI1; 2;, and Tian-xi SUN1; 2; *;
Author Affiliations
  • 1. Laboratory of Beam Technology of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875, China
  • show less
    DOI: 10.3964/j.issn.1000-0593(2021)09-2812-05 Cite this Article
    Ya-bing WANG, Shang-kun SHAO, Xue-peng SUN, Xiao-yun ZHANG, Hui-quan LI, Tian-xi SUN. Determination of Parameters of X-Ray Source Based on Tapered Glass Monocapillary X-Ray Condenser[J]. Spectroscopy and Spectral Analysis, 2021, 41(9): 2812 Copy Citation Text show less
    Sketch of the limiting case of single total reflection of the TGMXC
    Fig. 1. Sketch of the limiting case of single total reflection of the TGMXC
    Sketch of principle of reflecting X-rays of the TGMXC
    Fig. 2. Sketch of principle of reflecting X-rays of the TGMXC
    Sketch of the actual operating principle of the TGMXC
    Fig. 3. Sketch of the actual operating principle of the TGMXC
    Photographs of TGMXC(a): Outline of TGMXC; (b): Inner exit of TGMXC;(c): Inner entrance of TGMXC
    Fig. 4. Photographs of TGMXC
    (a): Outline of TGMXC; (b): Inner exit of TGMXC;(c): Inner entrance of TGMXC
    Focal spot size of the X-ray source vs.output power of the X-ray source
    Fig. 5. Focal spot size of the X-ray source vs.output power of the X-ray source
    Sketch of the experimental system
    Fig. 6. Sketch of the experimental system
    Normalized energy spectrums of the reflected X-rays of TGMXC on the logarithmic scale
    Fig. 7. Normalized energy spectrums of the reflected X-rays of TGMXC on the logarithmic scale
    Result of linear fitting
    Fig. 8. Result of linear fitting
    Z/μmEmax/keV
    1514.2
    2014.3
    2514.5
    3014.6
    3514.7
    4014.8
    4515.0
    5015.1
    Table 1. Calculation results of the maximum energy (Emax) corresponding to 8 focal spot sizes of the X-ray source
    Fb-e/mmEmax/kV
    20021.8
    25023.4
    30024.8
    35025.9
    40026.9
    45027.6
    50028.4
    55029.0
    Table 2. Calculation results of the maximum energy (Emax) corresponding to 8 distance between the berylium window of the X-ray source and the inner entrance of TGMXC (Fb-e)
    Ya-bing WANG, Shang-kun SHAO, Xue-peng SUN, Xiao-yun ZHANG, Hui-quan LI, Tian-xi SUN. Determination of Parameters of X-Ray Source Based on Tapered Glass Monocapillary X-Ray Condenser[J]. Spectroscopy and Spectral Analysis, 2021, 41(9): 2812