• Infrared and Laser Engineering
  • Vol. 53, Issue 4, 20230670 (2024)
Xu Zhang1,2, Qingzhou Mao1,2, Chunlin Shi3, Qingwu Hu1,2..., Guang Jin1,4, Hao Zhou1 and Yi Xie3|Show fewer author(s)
Author Affiliations
  • 1School of Remote Sensing and Information Engineering, Wuhan University, Wuhan 430079, China
  • 2Hubei Luojia Labortory, Wuhan 430079, China
  • 3Troops 61206, Beijing 100042, China
  • 4Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
  • show less
    DOI: 10.3788/IRLA20230670 Cite this Article
    Xu Zhang, Qingzhou Mao, Chunlin Shi, Qingwu Hu, Guang Jin, Hao Zhou, Yi Xie. Internal parameter calibration method of line-scan camera based on 2.5D calibration fan[J]. Infrared and Laser Engineering, 2024, 53(4): 20230670 Copy Citation Text show less
    References

    [1] Jing Wang, Liang Wei, Wenhao Xiang, et al. High-precision camera calibration method considering projected circular edge blur and eccentricity error. Infrared and Laser Engineering, 50, 20210130(2021).

    [2] Yangqing Shi, Caixia Chang, Xiaohong Liu, et al. Calibration methods and progress for internal and external parameters of area-array camera. Laser & Optoelectronics Progress, 58(24), 2400001(2021).

    [3] Xu Zhang, Chao Zhang, Yinhu Zhan, et al. A method of removing abnormal data from linear array total station astronomical measurement based on star position prediction. Acts Geodaetica et Cartographica Sinica, 52, 571-578(2023).

    [4] Zichen Wang, Ming Dai, Gang Li, et al. Calibration and analysis of line-scan camera based on virtual stereo pattern. Infrared and Laser Engineering, 43, 902-907(2014).

    [5] Guohui Wang, Kemao Qian. Review on line-scan camera calibration methods. Acta Optica Sinica, 40, 0111011(2022).

    [6] R Horaud, R Mohr, B Lorecki. On single-scanline camera calibration. IEEE Transaction on Robotics and Automation, 9, 71-75(1993).

    [7] C A Luna, M Mazo, J L Lazaro, . et al. Calibration of line-scan cameras. IEEE Transactions on Instrumentation Measurement, 59, 2185-2190(2010).

    [8] Dongdong Li, Gongjian Wen, Bingwei Hui, et al. Cross-ratio invariant based line scan camera geometric calibration with static linear data. Optics and Laser in Engineering, 62, 119-125(2014).

    [9] Kechen Song, Bin Hou, Menghui Niu, et al. Flexible line-scan camera calibration method using a coded eight trigrams pattern. Optics and Laser in Engineering, 110, 296-307(2018).

    [10] Ruiying Liao, Jigui Zhu, Linghui Yang, et al. Flexible calibration method for line-scan cameras using a stereo target with hollow stripes. Optics and Laser in Engineering, 113, 6-13(2019).

    [11] Draréni J, Roy S, Sturm P. Planebased calibration f linear cameras[J]. International Journal of Computer Vision , 2011, 91: 146156.

    [12] Hui Bingwei, Zhong Jinrong, et al. Derermination of line scan camera parameters via the direct linear transfmation[J]. Optics Engineering , 2012, 51(11): 113201.

    [13] Binwei Hui, Gongjian Wen, Peng Zhong. A novel line scan camera calibrations technique with an auxiliary frame camera. IEEE Transactions on Instrumentation Measurement, 62, 2567-2575(2013).

    [14] Bo Sun, Jigui Zhu, Linghui Yang, et al. Stereo line-scan sensor calibration for 3D shape measurement. Applic. Optics, 56, 7905-7913(2017).

    [15] Ming Yao, Zuyun Zhao, Bugao Xu. Geometric calibration of line-scan camera using a planar pattern. Journal of Electronic Imaging, 23(1), 013028(2014).

    [16] Menghui Niu, Kechen Song, Xin Wen, et al. The line scan camera calibration based on space rings group. IEEE Access, 6, 23711-23721(2018).

    [17] D Su, A Bender, S Sukkarieh. Improved cross-ratio invariant-based intrinsic calibration of a hyperspectral line-scan camera. Sensors, 18, 1885-1896(2018).

    [18] Wang Lan, Sun Bo, Long Changyu, et al. A novel method f calibrating intrinsic parameters of linear array cameras vased on collinear feature points[J]. Infrared Laser Engineering , 2015, 44(6): 18781883. (in Chinese)

    [19] Tsai R. A versatile camera calibration technique f highaccuracy 3D machine vision metrology using offtheshelf TV cameras lenses [J]. IEEE Journal of Robotics Automation , 1987, 3: 323344.

    [20] Fang Suping, Xia Xiaohua, Xiao Yan, et al. Lens disttion calibration method f linear array cameras[J]. Journal of Xi’an Jiaotong University , 2013, 47(1): 1114.

    [21] Shi Chunlin, Zhang Chao, Chen Changyuna, et al. Onedimensional maximum entropy image segmentation algithm based on the small field of view of measuring robot star map[J]. Acta Geodaetica et Cartographica Sinica , 2018, 47: 446454.

    [22] N Yamashita, M Fukushima. On the rate of convergence of the Levenberg-Marquardt method. Computing, 15, 239-249(2001).

    [23] Jinyan Fan. A modified Levenberg-Marquardt algorithm for singular system of nonlinear equations. Journal of Computational and Applied Mathematics, 21, 625-636(2003).

    [24] K Amini, F Rostami, G Caristi. An efficient Levenberg-Marquardt method with a new LM parameter for systems of nonlinear equations. Optimization, 5, 637-650(2018).

    Xu Zhang, Qingzhou Mao, Chunlin Shi, Qingwu Hu, Guang Jin, Hao Zhou, Yi Xie. Internal parameter calibration method of line-scan camera based on 2.5D calibration fan[J]. Infrared and Laser Engineering, 2024, 53(4): 20230670
    Download Citation