• Acta Optica Sinica
  • Vol. 36, Issue 10, 1011003 (2016)
He Qiyu1、2、*, Li Zhongliang1、2, Wang Xiangzhao1、2, Nan Nan1, and Lu Yu1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201636.1011003 Cite this Article Set citation alerts
    He Qiyu, Li Zhongliang, Wang Xiangzhao, Nan Nan, Lu Yu. Automated Retinal Layer Segmentation Based on Optical Coherence Tomographic Images[J]. Acta Optica Sinica, 2016, 36(10): 1011003 Copy Citation Text show less
    References

    [1] Mishra A, Wong A, Bizheva K, et al. Intra-retinal layer segmentation in optical coherence tomography images[J]. Optics Express, 2009, 17(26): 23719-23728.

    [2] Hu Zhixiong, Hao Bingtao, Liu Wenli, et al. Research on point spread function phantom fabrication and application for evaluating resolution performance of OCT systems[J]. Acta Optica Sinica, 2015, 35(4): 0417001.

    [3] Guo Xin, Wang Xiangzhao, Bu Peng, et al. Effects of scattering on spectral shape and depth resolution in Fourier domain optical coherence tomography[J]. Acta Optica Sinica, 2014, 34(1): 0117001.

    [4] Chiu S J, Li X T, Nicholas P, et al. Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation[J]. Optics Express, 2010, 18(18): 19413-19428.

    [5] Shi F, Chen X, Zhao H, et al. Automated 3-D retinal layer segmentation of macular optical coherence tomography images with serous pigment epithelial detachments[J]. IEEE Transactions on Medical Imaging, 2015, 34(2): 441-452.

    [6] Ishikawa H, Piette S, Liebmann J M, et al. Detecting the inner and outer borders of the retinal nerve fiber layer using optical coherence tomography[J]. Graefe′s Archive for Clinical and Experimental Ophthalmology, 2002, 240(5): 362-371.

    [7] Cha Y M, Han J H. High-accuracy retinal layer segmentation for optical coherence tomography using tracking kernels based on Gaussian mixture model[J]. IEEE Journal of Selected Topics in Quantum Electronics, 2014, 20(2): 6801010.

    [8] Gtzinger E, Pircher M, Baumann B, et al. Speckle noise reduction in high speed polarization sensitive spectral domain optical coherence tomography[J]. Optics Express, 2011, 19(15): 14568-14584.

    [9] Fercher A F, Hitzenberger C K, Kamp G, et al. Measurement of intraocular distances by backscattering spectral interferometry[J]. Optics Communications, 1995, 117(1): 43-48.

    [10] Schmitt J M, Xiang S H, Yung K M. Speckle in optical coherence tomography[J]. Journal of Biomedical Optics, 1999, 4(1): 95-105.

    [11] Fernández D C, Salinas H M, Puliafito C A. Automated detection of retinal layer structures on optical coherence tomography images[J]. Optics Express, 2005, 13(25): 10200-10216.

    [12] Ishikawa H, Stein D M, Wollstein G, et al. Macular segmentation with optical coherence tomography[J]. Investigative Ophthalmology & Visual Science, 2005, 46(6): 2012-2017.

    [13] Ahlers C, Simader C, Geitzenauer W, et al. Automatic segmentation in three-dimensional analysis of fibrovascular pigment epithelial detachment using high-definition optical coherence tomography[J]. British Journal of Ophthalmology, 2008, 92(2): 197-203.

    [14] Fabritius T, Makita S, Miura M, et al. Automated segmentation of the macula by optical coherence tomography[J]. Optics Express, 2009, 17(18): 15659-15669.

    [15] Mujat M, Chan R C, Cense B, et al. Retinal nerve fiber layer thickness map determined from optical coherence tomography images[J]. Optics Express, 2005, 13(23): 9480-9491.

    [16] Yazdanpanah A, Hamarneh G, Smith B, et al. Intra-retinal layer segmentation in optical coherence tomography using an active contour approach[C]. International Conference on Medical Image Computing and Computer-Assisted Intervention, 2009: 649-656.

    [17] Yazdanpanah A, Hamarneh G, Smith B R, et al. Segmentation of intra-retinal layers from optical coherence tomography images using an active contour approach[J]. IEEE Transactions on Medical Imaging, 2011, 30(2): 484-496.

    [18] Garvin M K, Abramoff M D, Wu X, et al. Automated 3-D intraretinal layer segmentation of macular spectral-domain optical coherence tomography images[J]. IEEE Transactions on Medical Imaging, 2009, 28(9): 1436-1447.

    [19] Yang Q, Reisman C A, Wang Z, et al. Automated layer segmentation of macular OCT images using dual-scale gradient information[J]. Optics Express, 2010, 18(20): 21293-21307.

    [20] Fuller A R, Zawadzki R J, Choi S, et al. Segmentation of three-dimensional retinal image data[J]. IEEE Transactions on Visualization and Computer Graphics, 2007, 13(6): 1719-1726.

    [21] Gtzinger E, Pircher M, Geitzenauer W, et al. Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography[J]. Optics Express, 2008, 16(21): 16410-16422.

    [22] Hee M R, Swanson E A, Fujimoto J G, et al. Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging[J]. Journal of the Optical Society of America B, 1992, 9(6): 903-908.

    [23] Wang L, Meng Z, Yao X S, et al. Adaptive speckle reduction in OCT volume data based on block-matching and 3-D filtering[J]. IEEE Photonics Technology Letters, 2012, 24(20): 1802-1804.

    [24] Dabov K, Foi A, Katkovnik V, et al. Image denoising by sparse 3-D transform-domain collaborative filtering[J]. IEEE Transactions on Image Processing, 2007, 16(8): 2080-2095.

    [25] Niu S, Chen Q, de Sisternes L, et al. Automated retinal layers segmentation in SD-OCT images using dual-gradient and spatial correlation smoothness constraint[J]. Computers in Biology Medicine, 2014, 54: 116-128.

    CLP Journals

    [1] Yingzhe Gao, Yi Yuan, Zhenhe Ma. High-Resolution Cortical Blood Flow Imaging Based on Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2019, 56(11): 111101

    [2] Ying Chang, Qingfeng Cui, Mingxu Piao. Optical Design of Michelson Interferometer Based Line-Field Swept Source Optical Coherence Tomography System[J]. Acta Optica Sinica, 2018, 38(6): 0608002

    [3] Yingzhe Gao, Yi Yuan, Zhenhe Ma. High-Resolution Cortical Blood Flow Imaging Based on Optical Coherence Tomography[J]. Laser & Optoelectronics Progress, 2019, 56(11): 111101

    [4] Yao Xinli, Ji Kunhao, Liu Guipeng, Shi Weisong, Gao Wanrong. Blood Flow Imaging by Optical Coherence Tomography Based on Speckle Variance and Doppler Algorithm[J]. Laser & Optoelectronics Progress, 2017, 54(3): 31702

    [5] Chen Yan, Li Zhongliang, Nan Nan, Bu Yang, Lu Yu, Song Siyu, Wang Xiangzhao. Wavelength Misalignment Analysis and Spectral Calibration for Fourier Domain Polarization-Sensitive Optical Coherence Tomography[J]. Chinese Journal of Lasers, 2018, 45(2): 207022

    [6] Gao Mingming, Wu Yue, Nan Jingchang. Adaptive Compression Reconstruction of Tomography System[J]. Laser & Optoelectronics Progress, 2018, 55(9): 91102

    He Qiyu, Li Zhongliang, Wang Xiangzhao, Nan Nan, Lu Yu. Automated Retinal Layer Segmentation Based on Optical Coherence Tomographic Images[J]. Acta Optica Sinica, 2016, 36(10): 1011003
    Download Citation