• Chinese Journal of Lasers
  • Vol. 51, Issue 8, 0801004 (2024)
Zhiqiang Wan1、2, Aibi Yang3, Guanghua Yang3, Shan Yu1、2, Ziye Hu3, Jilong Tang1、2、*, and Zhipeng Wei1
Author Affiliations
  • 1State Key Laboratory of High Power Semiconductor Laser, Changchun University of Science and Technology, Changchun 130022, Jilin , China
  • 2Zhongshan Institute, Changchun University of Science and Technology, Zhongshan 528437, Guangdong , China
  • 3Shenzhen JPT Opto-electronics Co., Ltd., Shenzhen 518110, Guangdong , China
  • show less
    DOI: 10.3788/CJL231147 Cite this Article Set citation alerts
    Zhiqiang Wan, Aibi Yang, Guanghua Yang, Shan Yu, Ziye Hu, Jilong Tang, Zhipeng Wei. Ring Light Spot Adjustable Signal Combiner with High Power and Large Core Diameter[J]. Chinese Journal of Lasers, 2024, 51(8): 0801004 Copy Citation Text show less
    Structure of (6+1)×1 signal combiner and cross sections of TFB and output fiber
    Fig. 1. Structure of (6+1)×1 signal combiner and cross sections of TFB and output fiber
    Transmission range of outer ring input beam on TFB cross section
    Fig. 2. Transmission range of outer ring input beam on TFB cross section
    Input fiber diameter versus taper ratio
    Fig. 3. Input fiber diameter versus taper ratio
    Proportion of three modes when TR is 0.2‒1.0
    Fig. 4. Proportion of three modes when TR is 0.2‒1.0
    Weld images of TFB. (a) Cross section of TFB; (b) installation diagram of welding machine; (c) side view of weld point
    Fig. 5. Weld images of TFB. (a) Cross section of TFB; (b) installation diagram of welding machine; (c) side view of weld point
    Experimental setup for combiner performance test
    Fig. 6. Experimental setup for combiner performance test
    Relationship between input power ratio and temperature
    Fig. 7. Relationship between input power ratio and temperature
    M2 test data at central port
    Fig. 8. M2 test data at central port
    M2 test data at outer ring port 2
    Fig. 9. M2 test data at outer ring port 2
    Experimental diagrams of environmental resistance test. (a) Experimental sample at low temperature of -30 ℃; (b) experimental sample at high temperature of 70 ℃; (c) efficiencies of each port in three cases
    Fig. 10. Experimental diagrams of environmental resistance test. (a) Experimental sample at low temperature of -30 ℃; (b) experimental sample at high temperature of 70 ℃; (c) efficiencies of each port in three cases
    Port No.Output power /kWEfficiency /%
    13.03698.2
    23.0398.0
    33.05898.9
    43.04398.4
    53.04698.5
    63.03698.2
    73.05298.7
    Table 1. Signal transmission efficiency of combiner at each port
    Port No.M2
    11.76
    285.8
    382.3
    488.2
    584.7
    685.7
    787.7
    Table 2. Beam quality of signal combiner at each port
    Zhiqiang Wan, Aibi Yang, Guanghua Yang, Shan Yu, Ziye Hu, Jilong Tang, Zhipeng Wei. Ring Light Spot Adjustable Signal Combiner with High Power and Large Core Diameter[J]. Chinese Journal of Lasers, 2024, 51(8): 0801004
    Download Citation