• Acta Optica Sinica
  • Vol. 31, Issue 5, 534002 (2011)
Chen Baomei1、2、*, Zhao Baosheng1, Hu Huijun1、2, Sheng Lizhi1、2, and Yan Qiurong1、2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: 10.3788/aos201131.0534002 Cite this Article Set citation alerts
    Chen Baomei, Zhao Baosheng, Hu Huijun, Sheng Lizhi, Yan Qiurong. Detection and Fitting of Pulse Profile for X-Ray Pulsar Navigation System[J]. Acta Optica Sinica, 2011, 31(5): 534002 Copy Citation Text show less
    References

    [1] J. H. Talor. Millisecond pulsars: nature′s most stable clocks [C]. Proc. IEEE. Las Vegas, 1991, 1054~1062

    [2] Yang Tinggao. Using pulsar clocks as time scale for spacecraft [J]. J. Time and Frequency, 2007, 30(2): 125~131

    [3] Paul S. Ray, Suneel I. Sheikh, Paul H. Graven et al.. Deep space navigation using celestial X-ray sources [C]. Proc. Ion NTM 2008, San Diego, CA, 2008, 101~109

    [4] Shuai Ping. The X-ray pulse navigation scheme of America and its implications[J]. Space International, 2006, (7): 7~10

    [5] Shuai Ping, Chen Shaolong, Wu Yifan et al.. Advance in X-ray pulsar navigation technology [J]. Chin. J. Space Sci., 2007, (2): 169~176

    [6] P. S. Ray, K. S. Wood, B. F. Phlips. Spacecraft navigation using X-ray pulsars [J]. J.Guid. Cont. & Dyn., 2006, 29(1): 49~63

    [7] Filter Transmission [DB/DL]. [2010-12-05] http://henke.lbl.gov/optical_constants/filter2.html

    [8] R. M. Rideout, J. F. Pearson, G. W. Fraser et al.. X-ray-induced radiation damages in CsI, Gadox, Y2O2 and Y2O3 thin film [J]. Nuclear Instruments and Methods in Physics Research Section A, 2001, 549(3): 543~551

    [9] A. S. Tremsin, O. H. W. Siegmund. Heat enhancement of radiation resistivity of evaporated CsI, KI and KBr photocathodes [J]. Nucl. Instr. Meth., 2000, A442: 337~341

    [10] Feifei Zhao, Baosheng Zhao, Xiaofeng Sai et al.. Influence of annealing temperature on the performances of Ge film and photon counting image system[J]. Chin. Opt. Lett., 2010, 8(4): 361~364

    [11] Xinghua Zhang, Baosheng Zhao, Zhenhua Miao et al.. Correction of ultraviolet single photon counting image distortion [J]. Chin. Opt. Lett., 2008, 6(9): 661~664

    [12] Gu Mu, Wang Di, Ni Chen et al.. A pulsed X-ray facility for fluorescent lifetime measurement based on micro-channel plate photomultiplier tube [J]. Acta Optica Sinica, 2008, 28(4): 813~816

    [13] L. W. Joseph. Micro-channel plate detector [J]. Nucl. Instr. & Meth., 1979, 142: 587~601

    [14] G. W. Fraser. X-Ray Detectors in Astronomy [M]. Cambridge: Cambridge University Press, 1989

    CLP Journals

    [1] Liu Duo, Qiang Pengfei, Li Linsen, Liu Zhe, Sheng Lizhi, Liu Yong′an, Zhao Baosheng. Multilayer Nested X-Ray Focusing Optical Device[J]. Acta Optica Sinica, 2016, 36(8): 834002

    [2] Liu Xiuping, Li Xiaoping, Sun Haifeng. X-Ray Pulsar Signal De-noising Using Lifting Scheme Wavelet[J]. Acta Optica Sinica, 2013, 33(3): 304002

    Chen Baomei, Zhao Baosheng, Hu Huijun, Sheng Lizhi, Yan Qiurong. Detection and Fitting of Pulse Profile for X-Ray Pulsar Navigation System[J]. Acta Optica Sinica, 2011, 31(5): 534002
    Download Citation