• Acta Optica Sinica
  • Vol. 29, Issue 10, 2650 (2009)
Li Hailiang1、2、*, Wu Jian2, Zhu Xiaoli1, Xie Changqing1, Liu Ming1, and Cao Leifeng3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    DOI: 10.3788/aos20092910.2650 Cite this Article Set citation alerts
    Li Hailiang, Wu Jian, Zhu Xiaoli, Xie Changqing, Liu Ming, Cao Leifeng. Fabrication and Study of 2000 l/mm X-Ray Self-Standing Transmission Gratings[J]. Acta Optica Sinica, 2009, 29(10): 2650 Copy Citation Text show less
    References

    [1] A. C. Brinkman,C. J. T. Gunsing,J. S. Kaastra et al.. First light measurements of Capella with the low energy transmission grating spectrometer aboard the Chandra X-ray observatory[J]. Astrophysical Journal Letters,2000,530(02):L111-L114

    [2] T. H. Markert,D. Dewey,J. E. Davis et al.. Modeling the diffraction efficiencies of the AXAF high-energy transmission gratings[C]. SPIE,1995,2518:424-427

    [3] K. A. Flanagan,T. T. Fang,C. Baluta et al.. Modeling the diffraction efficiencies of the AXAF high-energy transmission gratings:Ⅱ[C]. SPIE,1995,2808:650-676

    [4] D. A. Fedin,V. Kantsyrev,B. Bauer et al..“Polychromator”five channel X-ray/EUV spectrometer with imaging transmission grating for plasma diagnostics[C]. SPIE,1999,3764:80-84

    [5] Xu Xiangdong,Hong Yilin,Tian Yangchao et al.. Fabrication of self-supporting transmission gratings for plasma diagnostics [C]. SPIE,1999,3766:380-385

    [6] Wang Jie,Li Honghong,Wang Feng et al.. Commissions and experiments of soft X-ray magnetic circular dichroism beamline[J]. Nuclear Techniques,2005,28(07):489-495

    [7] Deng Jian,Zhou Fangchuan,Qing Ling et al.. Theoretical analysis of characteristics of the high efficiency high resolution soft X-ray transmission grating spectrograph[J]. Acta Optica Sinica,2000,20(5):647-653

    [8] C. R. Canizares,J. E. Davis,D. Dewey et al.. The chandra high energy transmission grating:design,fabrication,ground calibration and five years in flight [J]. Publications of the Astronomical Society of the Pacific,2005,117(07):1144-1171

    [9] Xu Xiangdong,Hong Yilin,Huo Tonglin et al.. The fabrication techniques for soft X-ray transmission gratings[J]. Optical Technology,2001,27(04):294-296

    [10] Zhu Weizhong,Wu Yanqing,Chen Min et al.. Optimized design of transmission grating used for 13.4 nm soft X-ray interference lithography[J]. Acta Optica Sinica,2008,28(07):1225-1230

    [11] Qiu Keqiang,Xu Xiangdong,Hong Yilin et al.. Design and fabrication of gold transmission phase gratings for soft X-rays[J]. Acta Physica Sinica,2008,57(10):6239-6244

    [12] Zhu Xiaoli,Ma Jie,Xie Changqing et al.. Fabrication of 3333 lp/mm soft X-ray transmission gratings[J]. Acta Optica Sinica,2008,28(06):1026-1030

    [13] M. L. Schattenburg,R. J. Aucoin,R. C. Fleming et al.. Fabrication of high energy X-ray transmission gratings for AXAF[C]. SPIE,1994,2280:181-190

    [14] Xu Xiangdong,Hong Yilin,Huo Tonglin et al.. Fabrication of Laminar grating for synchrotron radiation[J]. Optical Technology,2001,27(05):459-461

    [15] H. W. Schnopper,L. P. van Speybroeck,J. P. Delvaille et al.. Diffraction grating transmission efficiencies for XUV and soft X-ray[J]. Appl. Opt.,1977,16(04):1088-1091

    [16] Yang Jiamin,Yi Rongqing,Chen Zhenglin et al.. Study of transmission grating diffraction efficiency for soft X-rays[J]. Acta Physica Sinica,1998,47(4):0613-0618

    CLP Journals

    [1] Jiao Xiaoguang, Yin Cong, Shi Chunying, Qian Jin. Thermometry of Cr Laser Cooling via Knife-Edge[J]. Chinese Journal of Lasers, 2011, 38(7): 708004

    [2] Xie Changqing, Zhu Xiaoli, Niu Jiebing, Li Hailiang, Liu Ming, Chen Baoqin, Hu Yuan, Shi Lina. Micro- and Nano-Metal Structures Fabrication Technology and Applications[J]. Acta Optica Sinica, 2011, 31(9): 900128

    [3] Wang Haibin, Liu Quan, Wu Jianhong. Fabrication of Convex Blazed Grating By Ar+ Ion-Beam Etching[J]. Acta Optica Sinica, 2011, 31(4): 405002

    Li Hailiang, Wu Jian, Zhu Xiaoli, Xie Changqing, Liu Ming, Cao Leifeng. Fabrication and Study of 2000 l/mm X-Ray Self-Standing Transmission Gratings[J]. Acta Optica Sinica, 2009, 29(10): 2650
    Download Citation