• Acta Optica Sinica
  • Vol. 34, Issue 9, 912001 (2014)
He Xu* and Wu Guodong
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3788/aos201434.0912001 Cite this Article Set citation alerts
    He Xu, Wu Guodong. Procedure to Improve Alignment Accuracy of Collimator Reticle[J]. Acta Optica Sinica, 2014, 34(9): 912001 Copy Citation Text show less
    References

    [1] B McComas, R Rifelli, A Barto, et al.. Optical verification of the James Webb space telescope [C]. SPIE, 2006, 6271:62710A.

    [2] D Sabatke, S Meyer, N Siegel, et al.. Vertically configured collimator for cryogenic, vacuum testing of meter scale optical systems [C]. SPIE, 2007, 6671: 667108.

    [3] Pang Zhihai, Fan Xuewu, Chen Qinfang, et al.. Influence of surface-profile error of larger mirror on aberrations characteristics of optical system [J]. Acta Optica Sinica, 2013, 33(4): 0422002.

    [4] P J Lindberg. A collimator with variable focal length and tilted test plate for testing cameras [J]. J Opt Soc Am, 1952, 42(10): 748-751.

    [5] S C West, S H Bailey, J H Burge, et al.. Wavefront control of the large optics test and integration site (LOTIS) 6.5 m collimator [J]. Appl Opt, 2010, 49(18): 3522-3537.

    [6] A G Bugaenko, Y P Nikitin, N L Panteleev. Collimators for testing thermal-vision sights [J]. J Opt Technol, 2004, 71(2): 90-93.

    [7] A M Tareev. Testing collimators using a nonmisadjustable optical unit and a telescope [J]. J Opt Technol, 2000, 67(11): 1014-1017.

    [8] Zhao Man, Jiang Bo, Fan Xiuying, et al.. Measurement and analysis on the modulation transfer function of CCD camera [J]. Laser & Optoelectronics Progress, 2012, 49(7): 071201.

    [9] J H Burge, D W Kim. The thermal sieve: a diffractive baffle that provides thermal isolation of a cryogenic optical system from an ambient temperature collimator [C]. SPIE, 2012, 8442: 84421L.

    [10] A Krol, M A McGrath, B T Carey, et al.. Comparative studies of collimator performance in DaTscan (Ioflupane I-123) striatal SPECT [C]. SPIE, 2013, 8672: 867204.

    [11] Zhang Yaoyu, Li Min. A new test method of optical-axis parallelism for three-meter reflex light-tube [J]. Laser & Optoelectronics Progress, 2012, 49(12): 121205.

    [12] R M Bell, G C Robins, C Eugeni, et al.. LOTIS at completion of collimator integration [C]. SPIE, 2008, 7017: 70170D.

    [13] S B Hutchison, A Cochrane, S McCord, et al.. Updated status and capabilities for the LOTIS 6.5 meter collimator [C]. SPIE, 2008, 7106: 710618.

    [14] Zhang Lei, Zhang Lu, Hu Yuan. Research on testing method of wide distance optical axis parallelism [C]. SPIE, 2009, 7283: 72833O.

    [15] R O Naess. A measuring iInterferometer for high accuracy alignment [J]. Appl Opt, 1968, 7(11): 2315-2317.

    [16] M E Germain. Alignment of optical delay lines for long-baseline stellar interferometry [J]. J Opt Soc Am A, 2002, 19(1): 81-89.

    [17] K A Goldberg, P Naulleau, J Bokor. Fourier transforms interferometer alignment method [J]. Appl Opt, 2002, 41(8): 4477-4483.

    [18] S C Burkhart, E Bliss, P D Nicola, et al.. National ignition facility system alignment [J]. Appl Opt, 2011, 50(4): 1136-1157.

    [19] Han Juan, Duan Jiayou, Chen Jianjun, et al.. An alignment of primary and secondary mirrors for optical system in large telescopic [J]. Chinese J Lasers, 2012, 39(7): 0716001.

    [20] Cao Zhirui, Wu Guodong. Installation method of collimator reticle based on digital interferometer [J]. Electro-Optic Technology Application, 2013, 28(16): 4-7.

    [21] Cao Zhirui, Wu Guodong. The Alignment Procedure for Collimator Reticle According to Interference Principle, Chinese Patent: CN102853992A [P]. [2013-01-02].

    [22] He Xu, Wu Guodong. The Alignment Procedure for Collimator Reticle According to Interference Principle, Chinese Patent: CN103149013A [P]. [2013-06-12].

    [23] Danile Malacara. Optical Shop Testing (3rd Edition) [M]. Yang Li, Wu Fan Transl. Beijing: China Machine Press, 2012. 4.

    [24] Wang Lei, Wang Shouyin, Zhou Hu, et al.. Basic principles and use method of collimator [J]. Chinese J Scientific Instrument, 2006, 27(6): 980-982.

    He Xu, Wu Guodong. Procedure to Improve Alignment Accuracy of Collimator Reticle[J]. Acta Optica Sinica, 2014, 34(9): 912001
    Download Citation