• Infrared and Laser Engineering
  • Vol. 50, Issue 5, 20200345 (2021)
Yang Wang, Qingliang Meng*, Zhenming Zhao, Feng Yu, and Yu Zhao
Author Affiliations
  • Beijing Institute of Space Mechanics & Electricity, Beijing 100094, China
  • show less
    DOI: 10.3788/IRLA20200345 Cite this Article
    Yang Wang, Qingliang Meng, Zhenming Zhao, Feng Yu, Yu Zhao. Thermal design of all-optical path cold chain based on transmission-type cryogenic optical infrared camera[J]. Infrared and Laser Engineering, 2021, 50(5): 20200345 Copy Citation Text show less
    Schematic drawing of the camera configuration
    Fig. 1. Schematic drawing of the camera configuration
    Cooling design of optical system
    Fig. 2. Cooling design of optical system
    Schematic drawing of baffle and radiator
    Fig. 3. Schematic drawing of baffle and radiator
    Schematic diagram of optical system force-taking structure
    Fig. 4. Schematic diagram of optical system force-taking structure
    Schematic diagram of active temperature control system
    Fig. 5. Schematic diagram of active temperature control system
    Temperature curves of lenses under thermal simulation image and decontamination case condition
    Fig. 6. Temperature curves of lenses under thermal simulation image and decontamination case condition
    Temperature curves of lenses under thermal test image and decontamination case condition
    Fig. 7. Temperature curves of lenses under thermal test image and decontamination case condition
    ComponentsTemperature requirement/K
    Image caseDecontamination case
    Cold shield210±5313±5
    Optical lens210±5,axial temperature difference less than 5,temperature fluctuation less than ±0.5313±5
    Filter210±5,temperature fluctuation less than ±0.5313±5
    Lens of DewarLess than 235,temperature fluctuation less than ±0.4313±3
    Table 1. Temperature demands of the camera
    ComponentsPower/WThreshold/K
    Image caseDecontamination case
    Cold shield60205±0.3313±0.3
    Lens barrel40210±0.3313±0.3
    Cold window20210±0.3315±0.3
    Filter20210±0.3313±0.3
    Dewar20210±0.3313±0.3
    Table 2. Statistics of heating circuit
    CaseOrbit heat fluxThe state of thermal controlTemperature boundary of satellite/K
    Image caseMaximum heat flux throughout the life cycleImage model273
    Heat decontamination caseMinimum heat flux throughout the life cycleDecontamination model273
    Table 3. Operating conditions of test
    ComponentsTemperature/KAverage power/W
    Image caseDecontamination caseImage caseDecontamination case
    Cold shield202.8-205.3310.7-313.8019.2
    Lens barrel210.1-212.4312.1-315.14.314.1
    Optical lens210.3-211.3311.8-313.2
    Cold window210.3311.507
    Filter210.9-211.1310.97.19.2
    Lens of Dewar225.9-226.4312.704.2
    Radiator192.8-193.4240-240.5
    Table 4. Summary of test results