• NUCLEAR TECHNIQUES
  • Vol. 47, Issue 10, 100204 (2024)
Tao LYU1, Qian WANG1,2,*, and Qing LUO1,3,**
Author Affiliations
  • 1National Synchrotron Radiation Labratory, University of Science and Technology of China, Hefei 230027, China
  • 2Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
  • 3School of Nuclear Science and Technology, University of Science and Technology of China, Hefei 230027, China
  • show less
    DOI: 10.11889/j.0253-3219.2024.hjs.47.100204 Cite this Article
    Tao LYU, Qian WANG, Qing LUO. Design of bunch length and charge monitor based on cavity resonator for injector of Super Tau-Charm Facility[J]. NUCLEAR TECHNIQUES, 2024, 47(10): 100204 Copy Citation Text show less
    References

    [1] XUE Lei, DU Yingchao, HU Chao et al. Bunch charge monitoring system based on integrating current transformer[J]. High Power Laser and Particle Beams, 19, 1207-1210(2007).

    [2] Webber R C. Tutorial on beam current monitoring[C], 546, 83-84(2000).

    [3] CAO Shanshan, LENG Yongbin, YUAN Renxian et al. Methods study on high-resolution bunch charge measurement based on cavity monitor[J]. Nuclear Techniques, 44, 040101(2021).

    [4] Zhang W, Zhu D C, Sui Y F et al. Streak camera calibration for bunch length measurement at BEPC II[J]. Radiation Detection Technology and Methods, 5, 466-473(2021).

    [5] BAI Jin, CHEN Qushan, FAN Kuanjun. Bunch length diagnostic system based on RF deflecting cavity[J]. Atomic Energy Science and Technology, 53, 1607-1611(2019).

    [6] Steffen B, Casalbuoni S, Knabbe E A et al. Electro optic bunch length measurements at the VUV-FEL at DESY[C], 3111-3113.

    [7] Cao S S, Leng Y B, Yuan R X et al. An application of a cavity-based beam arrival time measurement system: beam energy measurement[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1045, 167456(2023).

    [8] ZHOU Yimei, LENG Yongbin, CHEN Jian et al. Optimization of bunch arrival time measurement algorithm for cavity probe[J]. Atomic Energy Science and Technology, 56, 2104-2112(2022).

    [9] Chen J, Cao S S, Leng Y B et al. Study of the optimal amplitude extraction algorithm for cavity BPM[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1012, 165627(2021).

    [10] Zhang A L, Xu L C, Sun J et al. Thermal research of a single crystal tungsten target positron source for the STCF project in China[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1039, 167107(2022).

    [11] WANG Qian, LUO Qing, SUN Baogen. Design and simulation of a single resonator beam length monitor[J]. High Power Laser and Particle Beams, 29, 125-129(2017).

    [12] Walston S, Boogert S, Chung C et al. Performance of a high resolution cavity beam position monitor system[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 578, 1-22(2007).

    [13] Kireeff C M. Nondestructive synchronous beam current monitor[J]. The Review of Scientific Instruments, 85, 125106(2014).

    [14] Lorenz R. Cavity beam position monitors[C], 451, 53-73(1998).

    [15] CAO Shanshan, LENG Yongbin, YUAN Renxian et al. Study on precise bunch current measurement based on dual cavity monitor[J]. Nuclear Techniques, 42, 040101(2019).

    [16] Wang Q, Luo Q, Sun B G. Design and performance study of an improved cavity bunch length monitor based on an optimized offline test scheme[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 968, 163975(2020).

    [17] Liapine A. Cavity beam position monitor for the TESLA energy spectrometer[C], 184(2003).

    [18] Guo J, Zhou Z R, Luo Q et al. Design and simulation of TM020 cavity bunch length monitor[J]. High Power Laser and Particle Beams, 28, 155-159(2016).

    [19] Bilanishvili S. Design and studying physical properties of cavity beam position monitors for electron accelerators[ED/OL]. https://iris.uniroma1.it/handle/11573/1546022

    [20] Maesaka H, Ego H, Inoue S et al. Sub-micron resolution rf cavity beam position monitor system at the SACLA XFEL facility[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 696, 66-74(2012).

    [21] Chen Z C, Zhou W M, Leng Y B et al. Subpicosecond beam length measurement study based on the TM010 mode[J]. Physical Review Special Topics - Accelerators and Beams, 16, 072801(2013).

    [22] LAI Longwei, LENG Yongbin, YAN Yingbing et al. Development and application of digital beam position measurement processor for FEL[J]. Nuclear Techniques, 41, 070402(2018).

    [23] CAO Shanshan. Key techniques study on beam arrival time and bunch charge measurement based on cavity-type monitors[D](2019).

    Tao LYU, Qian WANG, Qing LUO. Design of bunch length and charge monitor based on cavity resonator for injector of Super Tau-Charm Facility[J]. NUCLEAR TECHNIQUES, 2024, 47(10): 100204
    Download Citation