• Acta Photonica Sinica
  • Vol. 49, Issue 4, 0404002 (2020)
Wei-min DUAN1、2, Yuan-hui XIONG2, Zhen-wei CHEN2, Guang-bao YU1、2, Lin-mei LIU2, Fa-quan LI2, and Kui-jun WU2、*
Author Affiliations
  • 1University of Chinese Academy of Sciences, Beijing 100049, China
  • 2Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China
  • show less
    DOI: 10.3788/gzxb20204904.0404002 Cite this Article
    Wei-min DUAN, Yuan-hui XIONG, Zhen-wei CHEN, Guang-bao YU, Lin-mei LIU, Fa-quan LI, Kui-jun WU. Remote Sensing and Monitoring of Industrial SO2 and Carbon Black Particles with Ultraviolet Imaging Technology[J]. Acta Photonica Sinica, 2020, 49(4): 0404002 Copy Citation Text show less
    Normalized SO2 absorption cross section, solar scatter spectrum and filter transmission spectrum
    Fig. 1. Normalized SO2 absorption cross section, solar scatter spectrum and filter transmission spectrum
    Experimental equipment and optical circuit structure
    Fig. 2. Experimental equipment and optical circuit structure
    Target factory chimney
    Fig. 3. Target factory chimney
    Original images taken by the UV cameras
    Fig. 4. Original images taken by the UV cameras
    Emission image of SO2 after filtering the background
    Fig. 5. Emission image of SO2 after filtering the background
    Emission image of black carbon particles after filtering background
    Fig. 6. Emission image of black carbon particles after filtering background
    Emission rates of SO2 and carbon black particles
    Fig. 7. Emission rates of SO2 and carbon black particles
    InstrumentFeaturesParameter
    CameraResolution1200×1200
    Pixel size11 μm × 11 μm
    Frame rate5 fps@16-bit
    Dark noise100
    Exposure time (filter A)100 ms
    Exposure time (filter B)60 ms
    Focal length105 mm
    LensField angle9.8°
    Optical size18 mm
    FiltersFilter ACenter wavelength:310 nm FWHM:10 nm
    Filter BCenter wavelength:330 nm FWHM:10 nm
    Table 1. Instrument related parameters
    Source of errorError magnitude/(kg·h-1)Percentage
    Calibration coefficient0.180.25%
    Optical thickness0.650.89%
    Plume velocity3.014.1%
    Distance0.670.93%
    Table 2. Various error values of SO2 emission rate
    Wei-min DUAN, Yuan-hui XIONG, Zhen-wei CHEN, Guang-bao YU, Lin-mei LIU, Fa-quan LI, Kui-jun WU. Remote Sensing and Monitoring of Industrial SO2 and Carbon Black Particles with Ultraviolet Imaging Technology[J]. Acta Photonica Sinica, 2020, 49(4): 0404002
    Download Citation