• Optics and Precision Engineering
  • Vol. 18, Issue 7, 1491 (2010)
REN Jian-wei1,*, LIU Ze-xun1,2, WAN Zhi1, LI Xian-sheng1, and REN Jian-yue1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    DOI: Cite this Article
    REN Jian-wei, LIU Ze-xun, WAN Zhi, LI Xian-sheng, REN Jian-yue. Radiometric calibration of off-axis three-mirror-anastigmat space camera with wide viewing field[J]. Optics and Precision Engineering, 2010, 18(7): 1491 Copy Citation Text show less
    References

    [1] REN J W, WAN Z, LI X S, et al.. Radiation transfer characteristic and calibrating method for space optical remote sensor [J]. Opt. Precision Eng., 2007,15(8):1186-1190. (in Chinese)

    [2] LIU Y X. Research on the laboratory radiometric calibration of the TDICCD camera [J]. Opto-Electronic Engineering, 2007,34(5):71-74. (in Chinese)

    [3] GRAUE R, KAMPF D. Kayser-threde gmbH, et al. DIVA optical telescope [J]. SPIE, 2003,4854:9-20.

    [4] RISSE S,GEBHARDT A,DAMM C, et al.. Novel TMA telescope based on ultra precise metal mirrors [J]. SPIE, 2008,7010(16):1-8.

    [5] CHANG J, WENG Z C, JIANG H L, et al.. Design of long focal length space optical system with three reflective mirrors [J]. Opt. Precision Eng., 2001,9(4):315-318.

    [6] ZHANG L, JIA X Z. Design and optimization of trussed supporting structure for off-axis three-mirror reflective space camera [J]. Opt. Precision Eng., 2009,17(3):603-608.

    [7] LI Z L, XUE D L, ZHANG X J. Optical and mechanical design for long focal length and wide-field optical system [J]. Opt. Precision Eng., 2008,16(12):2485 -2490.

    [8] ZOU G Y, FAN X W. Baffle design and stray light analysis of the off-axis three-mirror telescope [J]. Acta Photonica Sinica, 2009,38(3):605 -609.

    [9] LIN D L. Radiation calibration of CBERS-1 ccd camera and image radiation correction [J]. Spacecraft Recovery & Remote Sensing, 2000,21(2):8 -13.

    [10] ZHANG J P, WU H Y, ZHOU W, et al..Experimental study of spectral radiance characteristics of large aperture integrating sphere [J]. Chinese Journal of Quantum Electronics, 2001,18(5):424-428.

    CLP Journals

    [1] GONG Da-peng, GUO Jiang, WANG Guo-liang, LIU Jin-guo, SUN Ji-ming, SHAO Ming-dong. Outdoor stereoscopic imaging of mapping camera with long focus off-axis three-mirror[J]. Optics and Precision Engineering, 2013, 21(1): 137

    [2] Zheng Liangliang, Zhang Guixiang, He Xiaojun, Qu Hongsong, Jin Guang. Research on Response Model of TDI CCD Image System[J]. Acta Optica Sinica, 2014, 34(11): 1104001

    [3] LI Xian-sheng, REN Jian-yue, REN Jian-wei, Zhang Xing-xiang, XUE Chang-xi. Establishment of image model for on-board space camera[J]. Optics and Precision Engineering, 2015, 23(7): 1852

    [4] JIANG Deng-biao, LI Bo, CHEN Qi-mei. CCD irradiance calibration algorithm for HDR image acquisition[J]. Optics and Precision Engineering, 2013, 21(11): 2980

    [5] REN Jian-wei, ZHANG Yan-qi, YE Zhao, QUAN Xian-rong. Establishment and application of CCD radiation response function matrix[J]. Optics and Precision Engineering, 2012, 20(5): 957

    [6] WAN Zhi, LI Bao-yong, LIU Ze-xun, LIU Hong-xing, REN Jian-wei. Spectral and radiometric calibrations for mapping satellite-1 camera[J]. Optics and Precision Engineering, 2015, 23(7): 1867

    [7] YANG Hui-sheng, ZHANG Yin-he, CHAI Fang-mao, XU Hong, LI Zhi-lai, GUAN Ying-jun. Design of focusing mechanism for off-axis TMA space camera[J]. Optics and Precision Engineering, 2013, 21(4): 948

    [8] ZHANG Chun-lei, XIANG Yang. Accuracy analysis of calibration for imaging spectrometer by using diffuser method[J]. Optics and Precision Engineering, 2011, 19(12): 2828

    REN Jian-wei, LIU Ze-xun, WAN Zhi, LI Xian-sheng, REN Jian-yue. Radiometric calibration of off-axis three-mirror-anastigmat space camera with wide viewing field[J]. Optics and Precision Engineering, 2010, 18(7): 1491
    Download Citation