• INFRARED
  • Vol. 42, Issue 3, 25 (2021)
Zhi-yong LIU* and Ji-fei YANG
Author Affiliations
  • [in Chinese]
  • show less
    DOI: 10.3969/j.issn.1672-8785.2021.03.005 Cite this Article
    LIU Zhi-yong, YANG Ji-fei. Research on Reliability Improvement of Bellows J--T Cooler[J]. INFRARED, 2021, 42(3): 25 Copy Citation Text show less

    Abstract

    As the important part of infrared detector component, bellows J-T coolers have been widely used. When used in the long-term vibration environment, the bellows as the self-control element will suffer from abnormal flow rate and failure of self-control. In order to improve the reliability of the cooler in the long-term vibration environment, the structure of the cooler is changed in this paper. The two-point support structure with diaphragm spring and PTFE guide ring is innovatively used which has a reliable radial support for the elastic moving parts of the cooler. It significantly improves the anti-vibration performance of the cooler, and has achieved good effect in practice. In addition, the research on the design in this paper also provides ideas for improving the anti-vibration performance of bellows J-T coolers in the future.
    LIU Zhi-yong, YANG Ji-fei. Research on Reliability Improvement of Bellows J--T Cooler[J]. INFRARED, 2021, 42(3): 25
    Download Citation